13. Input Sensitivity/Gain 

The standard settings are:1.4V,32dB,26dB,selection is independent for each channel. Use 
this function to match the amplifier's

 

sensitivity/gain with the other connected equipment. 

As option, is possible adjust the unit for any sensitivity/gain.Note that every increase of the 
gain will decrease the S/N ratio. 

14. Mode operation switches

Setup these switches for the desired operation mode. For reference see 

15. Speakon output connectors

The unit has four Speakon connectors as outputs: CH 1 and CH 2. Every one permit the con-
nection of both channels for stereo operation or parallel mode. For bridge operation the 
CH1 connector should be used. For reference see

16.  A.C. Power cable 

The unit have one A.C. power cable. Before connection, be sure that the cable is not frayed 
or broken. The connection must be made only in a plug with the electrical ground wire sys-
tem.

17. S.N. label

Every unit has a label indicating: the model, and the barcode serial number.

Figure 1.

 Figure 1.

Operation

Grounding

There is no ground lift switch or terminal on this amplifier. The signal ground is always 
floating via a resistor to chassis, and the grounding system is automatic. If a potential above 
0.6V is presents in between signal ground and chassis ground, a short circuit is introduced 
between the two, thereby enabling electrical protection. If a unit in the system is faulty, its 
mains fuse will blow due to this automatic ground system. If however you wish to tie the sig-
nal ground to chassis, connect the XLR-connector`s shell lug to pin 1. In the interest of 
safety never disconnect the earth pin on the AC power cord.
For all units that are FCC approved (radio interference), there is an AC mains filter. This fil-
ter needs the chassis ground for reference, otherwise a current loop is formed via the signal 
ground. Use the balanced input to avoid hum and interference.

Connecting Power and Circuit size requirements

Amplifier's power requirement are rated at idle, at 1/8 and 1/3 power ("severe" music condi-
tion).The maximum power current draw rating is limited only by the internal fuses. Consult 
the specification at the end of this manual for the power each amplifier will demand. Mains 
voltage must also be correct and the same as that printed on the rear of the amplifier. 
Damage caused by connecting the amplifier to improper AC voltage is not covered by any 
warranty.
Note: always switch off and disconnect the amplifier from mains voltage before making 
audio connections, and as an extra precaution, have the attenuators turned down during 
power-up.

Operating voltage

WARNING!

A label just below the mains cable on the rear of the amplifier indicates the AC mains volt-
age for which the amplifier is wired. Connect the power cable only to the AC source referred 
to on the label. The warranty will not cover damage caused by connecting to the wrong type 
of AC mains.

DXP6000 switch mode amplifiers use primary switching. The mains power is being rectified 
directly in front of the transformer, meaning that the power supply is insensitive to the mains 
frequency .

If the power plug is not appropriate for your country, it can be cut off and wired to a suitable 

connector in the following way:

BLACK or BROWN                                LIVE
WHITE or BLUE                                     NEUTRAL

GREEN or GREEN / YELLOW              EARTH

 

Once the AC connector is connected to a suitable AC supply, the amplifier can be started 
with the power switch. When you power up the amplifier it takes a couple of seconds to 
check its circuits(this is known as the 

soft start

 or 

slow start

 sequence), the fans then blow 

at high speed before going into 

idle

, and the two bottom green LEDs come on to show the 

output circuits are receiving the correct rail voltage.

Summary of Contents for DXP6000

Page 1: ...USER S MANUAL P R O F E S S I O N A L A U D I O...

Page 2: ......

Page 3: ...ual is subject to change without notice No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording of any kind SW...

Page 4: ...e Name of Dealer Full Address DATE OF PURCHASE Nature of the problem Be sure to describe the conditions that existed when the problem occurred and what attempts were made to correct it Other equipment...

Page 5: ...the packing materials in case shipping is required All productsbeingreturnedtothefactoryorservicecenterforrepairsmustbeshippedpre paid If the repairs made by NOVA or the NOVA Authorized Service Cente...

Page 6: ...mayresultinextensivedamage to the unit and the equipment rack Accessories are not needed Do not send the instruction manual cablesandanyotherhardware The DXP Seriesamplifier hasan automaticpower facto...

Page 7: ...With excessive inductionor magnetic fieldsdue to tranformersand transmitters Power factor correction DXP Series is a amplifier constructor to use power factor correction This unique feature ensures th...

Page 8: ...green SIGNAL 30dB 24dB 18dB 12dB 9dB 6dB 3dB 0dB LED indicatorslight respectively 5 Clip Limiter LED Each channel has a LED that light at the real clipping point more than 0 5 T H D and also indicates...

Page 9: ...coolingsystem to maintaina low even operating temperature Drawn by ainfinitely variable speedfans mounted insidethe unit airenters through the front grills with dustfilter andcourses through thecoolin...

Page 10: ...ed radio interference there is anAC mainsfilter Thisfil ter needs thechassis ground forreference otherwise acurrent loop isformed via thesignal ground Use thebalanced input toavoid hum andinterference...

Reviews: