![Nova Florida VELA COMPACT Installation Use And Care Manual Download Page 16](http://html1.mh-extra.com/html/nova-florida/vela-compact/vela-compact_installation-use-and-care-manual_1710428016.webp)
16
The boiler is designed as II2H3+ category and is to be installed in compliance with laws and standards in force in the country of instal-
lation.
3.2. Installation
Installation and maintenance procedures are to be implemented employing exclusively accessories and spare parts which
are approved and supplied by the manufacturer. Correct boiler operation is not guaranteed when using accessories and
spare parts which are not manufacturer approved and supplied.
3.2.1. Packaging
The boiler is shipped in a sturdy cardboard box.
Remove boiler from cardboard box and check its integrity.
The packing materials can be recycled: disposal of must be managed via specific waste collection sites.
Keep packaging out of the reach of children, as it may be source of danger.
The manufacturer shall not be held responsible for damage to people, animals, or property due to failure in following the above men-
tioned instructions.
Packaging includes one plastic bag containing:
a) installation, use and maintenance manual;
b) wall mounting template (pic. 7);
d) two screws and wall plugs in order to affix the boiler to the wall;
e) in CTFS model: one diaphragm for flue gas discharge (diameter 42.5);
f) in CTFS model: one sealing caps with gasket.
3.2.2. Choosing where to install the boiler
The following must be taken into account when choosing where to install the boiler:
- the indications given in … “Flue gas discharge system” paragraph;
- check the wall to be adequately well-built avoiding to fit the boiler on fragile walls;
- after the installation, check that 1 cm to the right and 1 cm to the left of the boiler was left for casing removal;
- Do not fit the boiler above any equipment that may prejudice proper operation (steam and grease vapor emitting kitchen appliances,
washing machines, etc.);
- Do not install boilers with a natural draught in rooms with a corrosive or very dusty atmosphere, such as hair salons, laundries, etc.,
as that may greatly reduce boiler lifespan.
3. INSTRUCTIONS FOR THE INSTALLER
3.1 INSTALLATION STANDARDS