WIRING/CONNECTION DIAGRAMS

PATTERN TABLE

TROUBLESHOOTING

ACCESSORIES

DIAGRAM (1): ON/OFF and Low Power using two toggle

switches. Flash pattern is: Quad Flash All Heads.

Selecting a flash pattern: In the table below, find the desired

flash pattern. Connect the wires marked

to the

'load' side of the ON/OFF switch.

Example: Diagram 1 uses pattern #4 (Quad Flash, All Heads).

To change this to pattern #6 (Mega flash, All Heads)
connect the YELLOW and BLUE wires to the switch.

POWER

Remove the remaining

wires, or connect them to Ground.

-

DIAGRAM (2): ON/OFF and Low Power using one DPDT

rocker switch. Flash pattern is: Quad Flash All Heads.

DIAGRAM (3): Selective switching of strobe head pairs. Low

Power selection. Flash pattern is: Quad Flash All Heads.

Blown Fuse

Erratic behavior (and/or) shutdown

: The X-PAK 904 will blow a fuse if the input

voltage is reversed. If this happens, first locate the wiring
fault, then replace the fuse with one of the same rating.

: The X-PAK 904 will

shut down if there is a short circuit condition on any one of
the strobe heads. If the electrical conductors connecting
the power supply to the strobe heads are exposed to water
a short circuit will result. The first sign is intermittent
operation, followed by complete shutdown of the strobe
system. To find the short circuit, unplug all strobe head
cables from the X-PAK 904. Test

cable/head at a time

until the problem is found.

one

The following accessories are available to make the
installation of the X-PAK 904 power supply even easier:

A Fully assembled switch panel which provides simple
On/Off and Low power control. Provides the same
functions as shown in Diagram (1)

A Fully assembled switch panel which allows selective
switching of strobe head pairs and also includes Low
power control.

A fully assembled switch panel which provides full
selection of all flash patterns as well as On/Off and Low
Power control.

ON/OFF - LOW POWER SWITCH PANEL

SELECTIVE SWITCHING PANEL

ROTARY SWITCH PANEL

Provides the same functions as shown in

Diagram (3)

All panels are pre-wired with 15'(standard) of cabling.

1

2

3

15

1

2

3

B

Fuse panel, Ignition or

accessory circuit.

BATTERY -

GND, vehicle
chassis.

RED

YELLOW

GREEN

BLUE

BLACK

VIOLET

NO CONNECTION

NO CONNECTION

POWER HARNESS

CONTROL HARNESS

Rocker Switch:

General purpose Double

Pole Double Throw.

Current through switch is

less than 1 amp.

Note:

Connections made to VIOLET,

YELLOW, GREEN, BLUE may be

made with 22-18AWG wire.

See FLASH PATTERN TABLE for more

flash pattern options.

SPST

SPST

1

2

3

15

1

2

3

B

Fuse panel, Ignition or

accessory circuit.

BATTERY -

GND, vehicle
chassis.

RED

YELLOW

GREEN

BLUE

BLACK

VIO

LET

NO CONNECTION

NO CONNECTION

LOW POWER

SWITCH

ON / OFF

SWITCH

NO CONNECTION

POWER HARNESS

CONTROL HARNESS

Toggle switches:

General purpose Single

Pole Single Throw.

Current through switch is

less than 1 amp.

Note:

Connections made to VIOLET,

YELLOW, GREEN, BLUE may be

made with 22-18AWG wire.

See FLASH PATTERN TABLE for more

flash pattern options.

15

SPST

SPST

SPST

1

2

3

1

2

3

B

Fuse panel, Ignition or

accessory circuit.

BATTERY -

GND, vehicle
chassis.

RED

YELLOW

GREEN

BLUE

BLACK

VIOLET

NO CONNECTION

NO CONNECTION

LOW POWER

SWITCH

HEADS 1+4

ON/OFF

HEADS 2+3

ON/OFF

NO CONNECTION

POWER HARNESS

CONTROL HARNESS

Toggle switches:

General purpose Single

Pole Single Throw.

Current through switch is

less than 1 amp.

PATTERN YELLOW GREEN

BLUE

FUNCTION

1

SHUTDOWN

2

POWER

Quad Flash, Head 2 ALT 3

3

POWER

Quad Flash, Head 1 ALT 4

4

POWER

POWER

Quad Flash, Head 1&3 ALT 2&4

5

POWER

Mega Flash, Head 2 ALT 3

6

POWER

POWER

Mega Flash, Head 1&3 ALT 2&4

7

POWER

POWER

Mega Flash, Head 1 ALT 4
When in High Power: Quintuple Flash, Head 1&3 ALT 2&4
When in Low Power: Double Flash, Head 1&3 ALT 2&4

ALT = "Alternates With"

POWER

POWER

POWER

8

Unused wires should either be
removed, or connected to Ground.

-

Unused wires should either be
removed, or connected to Ground.

-

Unused wires should either be
removed, or connected to Ground.

-