EN
G
LI
SH
14
FIXING POINTS:
REB-25 is equipped with 4 mounting holes M4 on a radius of 110.0 mm (see
figure). These holes are already threaded.
REB-25 is included in:
4 screws M4x60 countersunk flat head hex socket UNI 5933
DIN 7991-A in stainless steel A2
4 Flanged Nuts M4 DIN 6923 in stainless steel
References fastening SCREWS DIN 7991-A
ASSEMBLY PROCEDURE:
1. Run tracing on the surface respecting the references indicated holes.
2. Drill holes in the surface with the tip of 4.5 mm.
3. Make the seats for the heads of the screws DIN 7991-A with
countersink from 8.3 mm. This seat will avrere deep enough to
accommodate the entire head of the screw and allow grouting.
4. Place REB-25 at the holes made in Step 2.
5. Screw the 4 screws M4x60 DIN 7991-A.
6. Apply the 4 flanged nuts M4 DIN 6923.
7. Connect REB-25 amplifier unit according to the polarity of the same.
EN
G
LI
SH
15
Fasteners and Screw View
WARNING: To sonorize entirely and uniformly environment, a single
REB-25 is not enough for the stereo effect. Recommendations is the
use of at least two units.
REB-25 is suitable to make an active area of 10 square meters.