INVENTORY
IMPORTANT!
Never plug in or turn on unit without liquid in the vessel. Doing so could severely damage the
unit. Always plug the unit into a GFCI rated outlet. Do not move unit when in use. Sidewalls
will become hot during use.
ASSEMBLY & PREPARATION
Install bulkhead
1.
Remove the nut and collar from the main body. Do not remove the
o-ring.
2.
Feed the main body of the bulkhead, from the inside, through the
drilled port in the vessel. The o-ring should be pressed against the
inside of the vessel.
3.
Slide the collar, from the outside, onto the main body. Position the
small notch in the collar so it is facing straight up. The notch indicates
the curved side of the collar to ensure it sits flush against the
curvature of the vessel.
4.
Thread the nut onto the bulkhead and tighten against the collar.
5.
Thoroughly hand-tighten and if desired, use a wrench to tighten.
6.
Apply a few wraps of teflon tape to the external threads of the
bulkhead before installing the 1/2” NPT ball valve.
7.
Insert dip tube into assembly and position pick up as close to bottom
as possible.
As seen in the picture above.
Thoroughly clean the interior of the boiler with a cleaner like OneStep or
PBW.
Important.
Do not submerse the boiler. Contact with water can
destroy the electronics.
Main Body
O-Ring
Collar
Nut
Boiler Wall
Outside
Inside
Main Boiler
EZ Clean
™
Kettle Valve Kit
with Barb
This fully portable electric brew kettle uses a standard 120 volt outlet, enabling you to brew
anywhere, anytime. A fully integrated digital control and a built in timer ensure that steeping
grains are always kept at the perfect temperature for the perfect amount of time. Simply set
the temperature and you are ready to brew! Ditch the stove and create your own custom
brew cave anywhere you have an outlet!
™
E L E C T R I C B R E W K E T T L E