Installation Sequence
Pull or Push Side Mount
Page 3
• Track Assembly
Use of the hold open assembly pack on a
non hold open device will void the
UL® listing for this product.
Remove slider assembly parts from box
# 40-7940-0050-000 for Non Hold Open or
# 40-7940-0051-000 for Hold Open
and insert into channel in the order shown.
See illustration on Page 2 or 4.
Insert end caps into ends of track prior to installing.
Place the assembled
slide track against frame with the open side down,
stop and cushion blocks toward the hinge. Move
the slider to the opposite end of the slide track.
Secure slide track with 1/4-20 flat head phillips
drive mounting screws.
• Install track to frame.
With door closed.
With door open slightly.
Rotate arm to slider and place end over stud. Push
up on arm and tap gently to seat (to prevent stud
from turning during assembly). Secure with 1/4-20 x
5/8" long truss (rounded) head phillips drive screw
with thread lock. CAUTION: Closer arm is under
spring tension and may be difficult to rotate.
Open door to the angle
you want the door to stop. With the door held at
that location, slide stop with cushion block against
slider. Tighten the stop position screw (large set
screw) with 3/16" hex wrench (from screw pack)
until secure. Release door.
(see Page 5) before installing cover.
Slide insert into unused cover slot (see
illustration on Page 2 or 4).
Install cover using screws provided.
Thread pinion cap into pinion shaft.
Do not overtighten.
Fasten cover to mounting clips
with screws provided.
• Connect arm to track.
Pull side:
Push side:
• Set door stop angle.
• Adjust closer
• Install Cover.
Full Cover:
Narrow Cover:
Full Metal Cover:
Install cover using screws
provided.
• Install arm on closer pinion
-see arm indexing illustrations below.
(Top View)
Left hand
Right hand
Arm in position
Pinion Flat
Arm Indexing
PULL MOUNT
Start Here
Start Here
Start Here
Start Here
Reinstall Here
Rotate to Here
Rotate to Here
Arm in position
Pinion Flat
Arm Indexing
PUSH MOUNT
Right hand
Left hand
(Top View)
Pull mount:
Position slide arm
with counterbore
facing up and align
with pinion flat as
illustrated. Install
onto pinion.
Push mount:
With "S" & "L" valves
closed, place arm on
closer pinion shaft
with arm at a 45°
angle to frame face.
Rotate arm toward
hinge at least 50°.
Remove arm and
reinstall on pinion
with arm almost
parallel to frame
face, before pinion
shaft can rotate far
enough to create
interference with
door.
• Secure arm
with washer and flat head phillips drive arm screw with
thread lock.
from
illustrations on Page 1.
on Page 2 or Page 4 to locate fastener
holes on door and frame. See "Preparation for Fasteners" chart.
Prepare the frame for mounting track. Drill and tap holes
for 1/4-20 machine screws or #14 wood screws.
Prepare the door for mounting closer. Drill and tap (4)
holes for 1/4-20 machine screws, #14 wood screws,
3/8 diameter sex-nuts, or through bolts and grommet-nuts.
If drop plate is used (see Page 4), prepare holes for
8148/8548/8158 drop plate instead of closer.
Secure drop plate before mounting closer.
Position closer with:
- power adjustment shaft
from hinge
- power adjustment shaft
hinge
Secure mounting screws.
If using full metal cover, mounting clips must be slipped
under ends of closer when closer is being mounted.
Clips should project 1/4" (6 mm) from each end of closer.
Insert flat arm rod into arm tube with the
counterbore screw hole facing up. Align counterbore with the 3rd
hole in the arm tube and secure with 8-32 x 1/4 long hex socket
cap screw. See illustration on Page 2 or 4.
• Determine hand of door and type of installation
• Use template dimensions
Frame:
Door:
Note:
• Fasten closer to door or drop plate.
Pull side
away
Push side
toward
Note:
• Assemble Slide Arm.
80-9380-2212-020 (06-09)
Aluminum or
Wood
Preparation for Fasteners
Fasteners Door or Frame Drill Sizes
#14 type "A"
S.M. screw
Wood 7/32" (5.56mm)
Closer: 1-1/4" (32mm)
Track: 2-3/4" (70mm)
1/4" -20 machine Metal drill: #7 (.201")
screw tap: 1/4" -20
Sex-nuts and bolts Hollow Metal 9/32" (7.00mm) through
3/8" (9.50mm) door-face
opposite to closer
3/8" (9.50mm) through
Through-bolts and 9/32" (7.00mm) through;
grommet-nuts All 3/8" (9.50mm) dia. x
3/8" (10mm) deep door-
face opposite to closer
(Optional)