2.3  Electrical Installation 

 

Electrical  connections  are made to  th e s ensor module th rough a  s tandard 1 /2  inch N PT liq uid tig ht f lexible c onduit. T he 

nipple l ength may b e ch anged t o ex tend t he  outlet  box  if  desired.  Interconnection  cable  recommendations  are as  follows: 

stranded c opper, 22 t hrough 16 g age, br aided or  f oil w ith dr ain w ire s hielding 0. 05 

µ

F m aximum to tal m utual o r d irect 

capacitance, outer sheath insulated. Shrink tubing may be placed over any wires without insulation. For lengths over 100 feet, 

use 18 gage or larger, to a maximum of 1000 feet. If shielded twisted pair wire is used, do not cross channels. Keep each pair 

of complementary channel outputs together in a single twisted pair (e.g., A and A complement).   

 

CAUTION!

 

 

Reversing power and common will not damage the unit.  H owever, applying power to 

any of the sensor outputs may cause damage. 

 

Table 1. Signal Coding Table 

Signal 

Connector Pin 

Pigtail Cable 

MS 3102E18-IT# 

 

Common 

Z * 

No Connection 

Vcc (5-15 VDC) 

/B 

/A 

/Z * 

Shield 

 

10 

 

Black 

Green 

Blue 

Violet 

----- 

Red 

Yellow 

Gray 

Orange 

Braid 

 

*  Applies only to units with index pulse capability. 

#  Pinouts are for the sensors with the MS 3102E18IT connector

 

 

NOTE 

The shield in the sensor module is isolated from the frame of the encoder. For maximum 

noise immunity, the shield wire or pin should be connected to the shield of the cable and 

that of the drive or other receiving device. 

 

2.3.1  Quick Release Connector Hood Wiring 

 

To install the Quick Release Connector, perform the following steps. 

 

1.

 

Remove the four screws from the mating connector housing that hold the terminal block in place. Remove terminal block 

from housing. 

 

2.

 

Insert wiring through liquid tight flexible seal and mating connector housing. Leave enough wire exposed to comfortably 

reach the terminal block. Wire to terminal block according to wire code in Table 1. A similar wiring list is attached to 

enclosure. 

 

There are two orientations of the connector hood. The terminal block can be inserted 

either way so the connector hood points up or down. Choose the direction best for your 

application.  

NOTE 

 

4.  Tighten Liquid Tight fitting on housing. 

OPTIONAL

: In some hostile environments, seal between connector body and 

 

Sensor Module can be improved by smearing a sealant (silicone grease, etc.) on the neoprene seal of the connector. 

 

5. 

 

Mate connector into place on sensor mount and snap the two latches into place. If only one sensor is being installed,      

 

ensure cover plate is installed over other sensor hole. 

Summary of Contents for SLIM Tach HS56

Page 1: ... NorthStar Technoogies Inc 791 1010 00 Rev C 5 May 1999 Instruction Manual SLIM Tach HS56 Magnetoresistive Encoder Designed for use in 0 625 1 125 16mm 30mm Hollow Shaft Applications ...

Page 2: ... conjunction with the Customer that the product is required to be returned to NorthStar s factory for warranty repair a Return Goods Authorization RGA number will be issued For control purposes only those items identified with an RGA number may be returned to NorthStar Please make sure that the RGA number is clearly marked on the shipping label Packages missing an RGA number cannot be accepted by ...

Page 3: ... Hood Wiring 9 Figure 5 Sealed Industrial Latching Connector 10 2 4 Returning Equipment to NorthStar 10 Methods and apparatus disclosed and described herein have been developed solely on company funds of NorthStar Technologies Inc No government or other contractual support or relationship whatsoever has existed which in any way affects or mitigates proprietary rights of NorthStar Technologies Inc ...

Page 4: ...nnected and secured from all electrical power sources and 3 all accessory devices associates with the work area have been de energized If high potential insulation test is required follow procedures and precautions outlined in NEMA standards MG 1 Grounding Improperly grounding the frame of the machine can cause serious or fatal injury to personnel Grounding of the machine frame and structure shoul...

Page 5: ...already done for you in the encoder The anti rotation arm is very forgiving to any axial or radial motions that the motor might have yet is very torsionally non compliant Similar to NorthStar s heavy duty and mill duty encoders the SLIM Tach HS56 contains patented magneto resistive technology Magnetoresistive technology allows the NorthStar HS56 to be placed in the toughest environments The unit i...

Page 6: ...rrent Capability 150 mA typical 350 mA maximum worst case Connector 10 pin Epic style NEMA 4 12 industrial connector Suggested Cable 22 AWG 8 Conductor 18 length 4 twisted shield pairs Input Voltage 5 0 to 15 0 VDC Mechanical Specifications Maximum Operational Speed 3 600 RPM Shaft Requirements 0 625 1 125 0 000 0 0005 Bearings Sealed Max Radial Runout 0 015 total indicated run out Max Axial Trave...

Page 7: ...tages advise NorthStar immediately NorthStar cannot be responsible for any missing parts unless notified within 60 days of shipment The standard NorthStar Technologies Inc warranty is included on page 2 of this manual 2 1 Mounting the HS56 to a NEMA 180 or 56 C Face Motor 1 When the HS56 is to be mounted onto a motor with opposite end NEMA C Face insert the appropriate bolt i e 3 8 16 UNC or 13 UN...

Page 8: ...er the bolt tighten the hex standoff 4 Insert anti rotation rod end into the Hex standoff and tighten CAUTION The anchor bolt is designed for minimum inch of clearance between the fan and the fan shroud If there is not clearance the fan may hit the anchor bolt head on the inside of the fan shroud See drawing below The minimum shaft length for fan shroud mounting is 2 65 5 Slide the HS56 onto the a...

Page 9: ... pulse capability Pinouts are for the sensors with the MS 3102E18IT connector NOTE The shield in the sensor module is isolated from the frame of the encoder For maximum noise immunity the shield wire or pin should be connected to the shield of the cable and that of the drive or other receiving device 2 3 1 Quick Release Connector Hood Wiring To install the Quick Release Connector perform the follo...

Page 10: ...r must be obtained from a factory representative before returning the equipment to our service department When returning an instrument for service the following information must be provided before NorthStar can attempt any repair 1 Instrument model and serial number 2 User s name company address and phone number 3 Malfunction symptoms 4 Description of system 5 Returned Goods Authorization number C...

Page 11: ...NorthStar SLIM Tach HS56 Instruction Manual 11 5 May 1999 ...

Reviews: