Maintenance & Repair
36
Inspect and maintain your pressure washer as specified below in order to keep it in safe and optimal working
order. Follow all safety rules and recommended maintenance instructions.
WARNING
ALWAYS shut off water supply, bleed water pressure, turn off engine and disconnect the
spark plug before cleaning, adjusting, or servicing the pressure washer. After servicing,
make sure all guards and cover shields are replaced before using.
MAINTENANCE SCHEDULE
Item
Frequency
Remove dust/debris accumulation
As needed
Inspect fuel system
Each use
Inspect spray system
Each use
Clean inlet filter
Each use
Check tire pressure
Each use
Recharge and maintain battery
As specified in Battery Manufacturer's instructions.
Perform engine maintenance
As specified in Engine Owner’s manual
Change pump oil
•
After first 40 hours of use
•
Every 3 months or 500 hours of use after that
Maintain burner’s fuel filter / water separator
•
Drain water as needed
•
Change filter after every 500 hours of use
Descale coil
Annually, or more frequently as use and
performance require (see instructions)
Inspect and desoot coil if needed
Annually
Inspect/clean electrodes
Annually
Ignition coil
As needed
Check/tighten belts
Check belt tension after first 24 hours of use, then
routinely with each oil change. Tighten or change
belts as needed.
See detailed instructions for each maintenance item below.
(Note: For end-of-the-
season storage instructions, see the “Storage” section of this manual.)