background image

Northstar

 Explorer D210 

Installation and Operation Manual

4

Whenever power is applied the depth sounder is 
active and water depth is displayed. If the sonar 
signal does not show a bottom the display will 
indicate “- -”. This can occur if the water is aerated 
or the maximum depth is exceeded. 

Note:

 

The maximum depth decreases as boat speed 

increases.

Alarms

Two types of alarms can be set; the Deep Alarm 
and the Shallow Alarm. The Deep Alarm can be 
set as high as 184 metres (605 feet) while the 
Shallow Alarm can be set as low as 0.3 metre (1 
foot).

Whenever the water depth is greater than the 
Deep Alarm setting and the alarm is enabled an 
alarm will sound. The alarm repeats two short 
beeps and alternates DAL and the water depth 
on the display.

Whenever the water depth is less than the 
Shallow Alarm setting and the alarm is enabled 
an alarm will sound. The alarm repeats a single 
long beep and alternates SAL and the water 
depth on the display.

Alarms On/Off

Alarm settings are saved in memory.

To turn the alarm on, press 

 (ON). An arrow on 

the lower right corner of the display will show 
(next to the Alarm Bell), to indicate that the 
alarms are on.

   

To turn the alarms off, press 

 (OFF). The arrow 

in the lower right corner will extinguish.

   

Note:

 

The arrow will flash if alarms are turned ON 

but the shallow alarm is individually set to OFF. See 
next section.

Shallow Alarm

To set the shallow alarm:

1. Press   for three seconds. The display will 

show:

  

2.  After a few seconds the display will indicate 

the current Shallow Alarm depth setting.

3. Use   and 

 to change the value. If either 

key is held depressed for more than one 
second the reading will increase or decrease 
rapidly.

4.  When the alarm is set, exit by pressing both 

 and 

 simultaneously. Alternatively, if no 

keys are pressed for a period of 5 seconds the 
normal depth display will resume.

  

Press simultaneously to exit

Note:

 

If the reading is decreased to below

1.5 feet (or equivalent) the display will
show OFF and the alarm will be disabled. The alarm 
can also be disabled by pressing both 

 and 

 for 

5 seconds. The word OFF will be displayed but the 
alarm depth will be retained for future use.

Deep Alarm

To set the deep alarm:

1. Press   for three seconds. The display will 

show:

  

2.  After two seconds the display will indicate 

the current Deep Alarm depth setting.

1 Operation

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

Press for 3 

Seconds

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Press for 3 

Seconds

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

Summary of Contents for EXPLORER D210

Page 1: ...www northstarnav com Explorer D210 Installation and Operation Manual ...

Page 2: ... messages that follow this symbol to avoid possible injury or death WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avo...

Page 3: ...Deep Alarm 4 2InstrumentSetup 5 Keel Surface Offset 5 Transducer Setting 5 Units of Measure 5 3DualStationOperation 6 Master Slave Selection 7 Linked or Separate Selection 7 4Maintenance 8 5Installation 8 Instrument Installation 8 6Wiring 9 AppendixA Specifications 10 AppendixB Troubleshooting 11 AppendixC Howtocontactus 12 ...

Page 4: ... turn the alarms off press OFF The arrow in the lower right corner will extinguish Note The arrow will flash if alarms are turned ON but the shallow alarm is individually set to OFF See next section ShallowAlarm To set the shallow alarm 1 Press for three seconds The display will show 2 After a few seconds the display will indicate the current Shallow Alarm depth setting 3 Use and to change the val...

Page 5: ...ed on the left hand side of the display 6 To display depth below the keel enter the vertical distance between the bottom of the keel and the depth transducer as a negative value 7 To display depth below surface enter the vertical distance from the waterline to the depth transducer as a positive number no negative sign 8 To exit this mode press and hold both and simultaneously Alternatively if no k...

Page 6: ... and to change the value 4 To exit this mode press and hold both and simultaneously Alternatively if no keys are pressed for a period of 5 seconds normal depth display will resume Press simultaneously The display will now indicate the current water depth in the selected display unit Multiple Explorer 210 instruments can be installed on a single vessel These instruments can be connected together an...

Page 7: ... changed on the master will be automatically changed in the slave instrument Note The keel offset and units of measure should only be changed on the Master instrument If independent settings are required the link feature can be disabled To enable or disable the linked mode 1 Apply power while holding down Hold down during power up 2 When the unit is on The display will first indicate the current d...

Page 8: ...unting nut until the bracket is secure 6 Connect the power cord at the back of the instrument to a 12 V power supply which is active whenever the ignition switch is on The red lead should be connected to the positive terminal of the power supply via a 1 amp fuse or a 1 amp circuit breaker The black lead should be connected to the negative terminal Your depth sounder is designed for years of troubl...

Page 9: ...l to complete circuit If unused then tape to avoid shorting BrownDatainput output Your Explorer D210 can be used as a repeater for another DPT or DBT NEMA depth sounder If unused then tape to avoid shorting Bracket Buzzer RCA Jack Connector 600 mm 24 inch Power Cord Black Red Orange Brown 6 Wiring If unsure about wiring contact your nearest Northstar dealer ...

Page 10: ...Operating Voltage 9 5 V DC to 16 5 V DC Operating Temperature 0 C to 50 C 32 F to 122 F Current Drain 150 mA max including internal buzzer Data Input Output Single wire data output Input Dual station mode outputs NMEA sentences Dual station accepts NMEA sentences In the linked mode a dual station pair also transfer function settings eg Alarm on off NMEA Output DPT NMEA Input DPT and DBT External B...

Page 11: ... free of corrosion Erraticreadingswhilemoored 1 Check transducer for growth or multiple coats of paint Appendix B Troubleshooting Erraticreadingswhilemoving 1 Cavitation air under the face of the transducer Review installation and reinstall if necessary Erraticreadingsonlywhileengineisrunning 1 Re route power and transducer cables away from engine ignition wires and battery cables 2 Add feed throu...

Page 12: ...ROPE Unit 2 Ocean Quay Belvidere Rd Southampton SO14 5QY ENGLAND Ph 44 2380 339922 Fax 44 2380 330345 northstaruk northstarnav com AUSTRALIA PO Box 479 Gladesville NSW 2111 AUSTRALIA Ph 61 2 9879 9060 Fax 61 2 9879 9009 northstaraus northstarnav com NEW ZEALAND PO Box 68 155 Newton Auckland Auckland NEW ZEALAND Ph 64 9 481 0500 Fax 64 9 481 0590 northstarnz northstarnav com ...