Northstar
Explorer D210
Installation and Operation Manual
10
• Size
Mount: 51 mm (2”) diameter hole
Depth behind face plate: 95 mm (3.75”) max.
Display: 3-character LCD
• Color
Black
bezel.
• Backlighting
Red colored diffused lighting for display.
• Water
Integrity
Front will withstand direct water spray.
• Depth/Alarm
Range
2.0-600
feet
0.6-184
metres
0.3-100
fathoms
(to 9.9 in tenths)
• Sensitivity
Better than 0.05 mV RMS at 200 feet.
• Transmit
Power
36 W RMS nominal at 13.6 V DC.
• Transducer
200 kHz 1900 pF/600 W parallel.
• Display
Updating
1
second.
• Operating
Voltage
9.5 V DC to 16.5 V DC.
• Operating
Temperature
0°C to 50°C (32°F to 122°F).
• Current
Drain
150 mA max, including internal buzzer.
• Data
Input/Output
Single
wire
data
output/Input.
Dual station mode outputs NMEA sentences.
Dual station accepts NMEA sentences. In the
linked mode a dual station pair also transfer
function settings eg. Alarm on/off.
• NMEA
Output
DPT.
• NMEA
Input
DPT and DBT.
•
External Buzzer Output
12 V DC Buzzer, 100 mA max.
• RF
Interference
<6 dB quieting on any marine radio channel
(with 3 dB gain antenna) within one meter
of the instrument. Complies with CE EMC
standards EN50081-1 and EN50082-1.
Appendix A - Specifications
Display is backlit for
Night operation
Alarm On/
Change Value up
Alarm Off/
Change Value
Down