Maintenance & Repair (cont’d)
37
Check GFCI
(if equipped)
Once a month, test the Ground Fault Circuit Interrupter (GFCI) to
protect against electrical shock due to failure of the GFCI.
(Only for
those models equipped with GFCI.)
To test the GFCI:
1.
Depress the TEST button. The RESET button should extend from the
receptacle. If the RESET button does not extend, contact Northern Tool
for replacement parts.
2.
Restore power to the GFCI by firmly pressing the RESET button back
into the receptacle until an audible click is heard.
Clean & inspect
spark arrestor
(if equipped)
Clean and inspect the spark arrestor muffler
If the engine is equipped with a spark arrester muffler, clean and inspect it
regularly (follow manufacturer’s service instructions). Replace if damaged.
Keep generator
clean
Keep generator clean.
If dust or debris accumulates on the generator, clean the generator with a
damp cloth or soft bristle brush. Do not allow air intakes to become blocked.
Note: Do not spray generator with a garden hose or pressure washer.
Water may enter the generator and cause damage to the rotor, stator, or
internal windings.
Recharge and
maintain battery
(if electric start)
Inspect, recharge, and maintain your battery according to your battery
manufacturer’s instructions.
(Only for those models equipped with electric
start.)
Do not store with battery charger always connected. Batteries that are over-
charged can boil themselves dry and produce excessive amounts of hydrogen,
an explosive gas.
IMPORTANT:
If a part needs replacement, only use parts that meet the manufacturer’s specifications. Replace-
ment parts that do not meet specifications may result in a safety hazard or poor operation of the
generator.
Contact NorthStar Product Support at 1-800-270-0810
for any questions, problems, or parts orders.
Summary of Contents for 165601
Page 2: ...Hazard Signal Word Definitions 2 ...
Page 43: ...Generator Exploded View Rev O 3 Item s 165601 165603 165604 43 ...
Page 45: ...Generator Exploded View Rev O 3 Item s 165605 165606 165607 45 ...
Page 47: ...Control Panel Parts List Rev O 3 47 Item 165601 Item 165603 Item 165604 ...
Page 48: ...Control Panel Parts List Rev O 3 48 Item 165605 Item 165606 Item 165607 ...
Page 50: ...Generator Head Exploded Views Rev O 3 Item s 165601 165603 165604 165605 50 ...
Page 52: ...Generator Head Exploded Views Rev O 3 Item s 165606 165607 52 ...
Page 54: ...54 This page has intentionally been left blank ...
Page 56: ...56 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com ...