Installation / Initial Set-Up
22
Adequate cooling
ventilation
The generator needs adequate, unobstructed flow of air to allow for
proper cooling of engine and generator head.
WARNING:
Heat build-up from inadequate ventilation can result in fire, posing a
serious risk to nearby persons and structures.
Situate so there is adequate clearance around generator to allow for
cooling airflow so that heat does not build up.
Never place the generator immediately adjacent to a building or other
structure – allow at least a 7’ clearance.
Do not run the generator in close proximity to other heat-generating
equipment, such as another generator. The combined heat that is
generated may raise air temperature in the immediate area and there will
not be adequate cooling ventilation.
Do not allow debris to accumulate and block airflow.
Do not operate with a tarp, blanket, or cover surrounding the generator.
No wet conditions Choose a location where the generator will NOT be exposed to rain,
snow, or direct sunlight.
Exposure to water can cause electric shock.
You
may
operate the generator under an outdoor, canopy-like structure of
heat-resistant material that is open on all sides. Make sure that all parts of
canopy are at least 7’ from exhaust, and allow for adequate clearance above
generator so that heat does not build up.
Hot exhaust
clearance
The exhaust gas from your generator is extremely hot and can cause
combustible materials to catch on fire.
Make sure your generator’s exhaust system is at least 7 feet from all
combustible materials and buildings/structures.
Equip the engine with a spark arrestor if the generator will be used near
any ignitable forest, brush, or grassy land. (See the “Specifications”
section of this manual to determine if your generator is already equipped.)
Make sure you comply with applicable local, state, and federal codes.
Keep a fire extinguisher rated “ABC” nearby. Keep it properly charged
and be familiar with its use.
Away from
dust/dirt
Do not use the generator in extremely dusty or dirty conditions.
Excessive dust and dirt can cause premature failure of the machine.
Hearing
protection
Generators can produce noise levels of up to 95 dB in close proximity,
which can be dangerous to human hearing with prolonged exposure.
Hearing protection may be required for persons working within 15-20 feet of
the running generator for an extended period of time.
WARNING:
Never attempt to attach ductwork to the muffler system to lower noise
levels. This could cause hot air deflection, heat build-up, and
increased exhaust back-pressure, resulting in possible exhaust leakage
or damage to the generator.
Summary of Contents for 165601
Page 2: ...Hazard Signal Word Definitions 2 ...
Page 43: ...Generator Exploded View Rev O 3 Item s 165601 165603 165604 43 ...
Page 45: ...Generator Exploded View Rev O 3 Item s 165605 165606 165607 45 ...
Page 47: ...Control Panel Parts List Rev O 3 47 Item 165601 Item 165603 Item 165604 ...
Page 48: ...Control Panel Parts List Rev O 3 48 Item 165605 Item 165606 Item 165607 ...
Page 50: ...Generator Head Exploded Views Rev O 3 Item s 165601 165603 165604 165605 50 ...
Page 52: ...Generator Head Exploded Views Rev O 3 Item s 165606 165607 52 ...
Page 54: ...54 This page has intentionally been left blank ...
Page 56: ...56 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com ...