21
Limit length of electric line when using the extension line or distributed network is: less than 60m for
cables of 1.5mm2, and less than 100m for cables of 2.5mm2
6.2 DC application
1. DC terminals are only for charging 12V battery.
2. Set the air switch at "OFF" position while charging. On the 12V output terminals, a charge switch can
be connected so the switch can be used for on-and-off purpose.
3. Concerning the automatic type battery with the leads, be sure to disconnect the negative leads of the
battery while charging.
CAUTION
■
Connect the positive and negative poles of the battery with the positive and negative poles of DC
terminals separately. Do not confuse them, otherwise the battery and generating set will burn out.
■
Do not connect the positive pole of the battery with its negative pole, otherwise the generating set
damage will result.
■
When a large capacity battery is charged, excessive current flows, the fuse for the direct current will
burn out.
■
Do not run the generating set while it is still connected with the battery.
■
Do not use DC12V and AC at the same time.
CAUTION
■
To prevent from creating a spark near the battery, always connect the charging cables to the battery
first and only then to the generating set. When disconnecting, you should disconnect the cables at the
generating set first.
■
Charge the battery at a well-ventilated place.
■
Before charging, remove the cap from each cell of the battery.
■
Stop charging if the electrolyte temperature exceed 45
℃