3625 Cincinnati Avenue, Rocklin CA 95765 ● 855-388-7422 ● [email protected]   

Pairing Push Button 

Reset / Pairing (Join or Leave Network Group) 

Push 

Duration 

LED 

Status 

Description 

1 – 3 sec 

Red Blink 

Join/Host Network Group 

5 – 8 sec 

Amber Blink 

Once -> OFF   

Leave Network Group 

12 - 30 sec 

OFF -> Amber 

Blink Once 

Reset to Default Network 

Group 

 

Power

 

Input Operating Voltage 

DC 56V / 65W (Included) 

Power Consumption 

1.5W (w/o power forwarding)   

Mechanical & Environmental

 

Weight   

176g (6.2 oz) 

Dimensions (W × L × H) 

38 x120 x 33mm (1.5”x4.7”x1.3”) 

Operation Temperature 

-20C ~ +60°C (-4°F ~ 140°F) 

Storage Temperature 

-30

C ~ 80

C (-22°F ~ 176°F) 

Humidity 

20% to 85% RH. (non-condensing) 

1. All 

EOCCPK

 are paired to the same network group by factory default, they can be installed directly with no 

need for pairing again. 

2. The transmission system consists of one transceiver at NVR side and one transceiver that connects to IP 

cameras or other IP devices. 

3. When using two or more transmission systems at the NVR or Control room – if there is no cross-talk 

between the two systems then there is no need to perform the pairing process.     

4. To 

join

 another network group, must 

leave

 current group first, then do the group

 join

.

 

 

Transmission Distance with Power Delivered: 

Power Delivered   

 
Power Source   

Not using   

PoE output 

5.5W 

7W 

9W 

12W 

17W 

Maximum Coax RG6. Data Link Distance 

 

56VDC Power Supplied 

2000m 

600m 

500m 

400m 

300m 

200m 

Maximum Coax RG59. Data Link Distance

 

1800m 

500m 

450m 

350m 

250m 

150m 

 
 

Packing 

    1. EOCCPK Transceiver 

  ×2 

    2. User Manual 

  ×1 

    3. Wall Mount Hardware Kit 

  ×2 

    4. DC 56V / 65W Power Adaptor  ×1

 

 

   
   

Summary of Contents for EOCCPK

Page 1: ...l cable to IP POE cameras Up to 600 Meter transmission distance when using RG6 cable 1640ft using RG59 cable Built in 6KV surge protection at BNC and 4KV at RJ45 ports SPECIFICATIONS MODEL EOCCPK Extender Interface Connector Type 1x BNC Cable Type 75 ohm RG59 RG6 or RG11 video grade coaxial cable Max Transmission Distance 600m 1968ft for RG6 coaxial cable 500m 1640ft for RG59 Ethernet Interface Co...

Page 2: ...e same network group by factory default they can be installed directly with no need for pairing again 2 The transmission system consists of one transceiver at NVR side and one transceiver that connects to IP cameras or other IP devices 3 When using two or more transmission systems at the NVR or Control room if there is no cross talk between the two systems then there is no need to perform the pair...

Page 3: ...oin leave RESET for factory default network group CONNECTION DIAGRAM Notice Cable quality camera bandwidth used and power supply noise can cause actual distances which may not match the diagram below Application Diagram 1 Single Camera EoC with PoE Transmission System Application Diagram 2 Single Camera EoC with PoE Transmission System Alternate Power Supply Location Monitor DC 56V 65W Max 600m RG...

Page 4: ...1 3 seconds the LED color will turn RED and start blinking Step 4 Slave Side Transceiver Leaving Current Network Group On the transceiver at the Remote side close to IP camera device using a straightened paper clip to push the small button for 5 8 seconds the LED color will turn AMBER blink once then turn OFF Step 5 Slave Side Transceiver Joining New Network Group EOC transceivers at Remote side c...

Reviews: