Specifications 2-3
M5212 ACD Set
General Description, Installation, and Maintenance BCS33 and up
Table 2-3xxx
Random electronic failures and MTBF
Item
% Failures per Year
Handset Receiver
0.9
Handset Transmitter
0.5
Alphanumeric Display
1.2
Wall Transformer
0.3
Hookswitch
0.3
Electronic Components
4.4
Total
7.6% MTBF = 13.16 years
Table 2-4xxx
Mechanical Failure
Item
One failure per years
Handset Cord
70
Line Cord
30
Housing
200
All Mechanical Components
19
Recommended headsets
Northern Telecom has fully tested the following headsets and adapters and
found them to be acceptable from both safety and performance standards:
Note: ”RJ” usually refers to headset types with electret microphones. ”PJ”
usually refers to headset types with carbon microphones. For proper operation
of the headset, ensure that the appropriate type of headset is plugged into the
matching jack on the bottom of the set.
Table 2-5xxx
Recommended headsets
Manufacturer
Type
Model no.
Recommended
Volume Settings
Plantronics
PJ
HSB552-1, Supra
VOL. II
Plantronics
RJ
MHB528-2, Supra
00110101 VOL. I