3-8 Alarm clearing procedures
Minor
(continued)
PM LCM
(continued)
297-2101-504 Standard 02.01 December 1991
Clearing a PM LCM Minor alarm
(continued)
Step
Action
12
Return the drawer to service by typing
>RTS DRWR drwr_no
and pressing the Enter key.
↵
where
drwr_no
is the number of the LSG to be returned to service
(0 to 19)
Note: Both LSGs must be returned to service.
If the RTS command
Do
passed and the drawer is in
service (.)
passed and the drawer is in
service (.), but other drawers are
either system busy (S) or manual
busy (M)
failed and you
have not replaced all
the cards in the list recorded in
step 9
failed and you have replaced all the
cards in the list recorded in step 9
failed and a card list
is not
generated
step 15
step 9
step 13
step 14
step 14
13
See the chapter titled “Card replacement procedures” in this document to
replace the next card on the list, and return to step 12 in this procedure.
14
For further assistance, contact the personnel responsible for the next
level of support.
15
You have completed this procedure.
End