Northern Lights Lugger M843NW2 Operator'S Manual Download Page 5

OM843NW2  10/09

5

Serial Numbers

Safety Rules

CAUTION:  This symbol is used throughout
this book to alert you to possible danger areas.
Please take special notice of these sections.  

A warranty registration certifi cate is supplied 
with your set. It entitles the original purchaser of our 
equipment to a warranty covering material 
or assembly faults. The extent of coverage is described 
in the Limited Warranty Statement. We recommend 
that you study the statement carefully.

NOTE:

 If the warranty is to apply, the servicing 

instructions outlined in this manual must be 
followed. If further information is needed, please con-
tact an authorized dealer or the factory.

CAUTION:

  Accident reports show that careless use of engines causes a high percentage of accidents. 

You can avoid accidents by observing these safety rules. Study these rules carefully and enforce them on the job.

•  Never leave engine without proper security.

•  Turn the coolant tank cap slowly to relieve pressure 

before removing. Add coolant only when the engine 
is stopped and cool.

• Mount 

fi re extinguisher near engine.

•  Always disconnect the battery ground strap before 

making adjustments.

•  Operate engines in properly ventilated areas.

•  Keep trash and other objects away from engine.

• Escaping 

fl uids under pressure can penetrate your 

skin. Use a piece of cardboard or wood, not your 
hands, to search for leaks.

•  Avoid wearing loose clothing without a belt when 

working around engines.

•  Do not oil or grease engine while it is running.

•  Use caution in handling fuel. Never refuel a hot 

or running engine. Do not smoke while fi lling fuel 
tank or servicing fuel system.

Your set has three serial numbers:  

1

  an engine number stamped 

on the block,  

2

  a generator plate, and  

3

 a generator set plate. 

Use the serial number on the generator set plate when ordering parts 
or in correspondence. The generator set plate is found on the service 
side of the generator and resembles the drawing at left. 

Generator set serial number plate.

Warranty

•  Keep your hands, feet, hair and clothing away from 

power-driven parts.

•  Check for any loose electrical connections or faulty 

wiring.

•  Engines should be operated only by knowledgeable, 

qualifi ed personnel.

•  Look completely around engine to make sure that 

everything is clear before starting.

•  Do not operate an engine that isn't in proper work-

ing order. If an unsafe operating condition is noted, 
tag the set and control panel so others will also 
know about the problem.

• Provide 

fi rst aid kits.

Summary of Contents for Lugger M843NW2

Page 1: ...OM843NW2 For Model M843NW2 OPERATOR S MANUAL Marine Generators Marine Diesel Engines Land Based Generators...

Page 2: ...other reproductive harm CALIFORNIA Proposition 65 Warning Northern Lights 4420 14th Avenue N W Seattle WA 98107 Tel 206 789 3880 Fax 206 782 5455 Copyright 2009 Northern Lights Inc All rights reserved...

Page 3: ...PONENT LOCATIONS M843NW2 Marine Generator 6 CONTROL PANELS 7 OPERATING PROCEDURES Break in Period 8 Before Starting 8 Starting 8 Operating 8 Stopping 8 Shutdowns and Alarms 9 Spare Parts 9 SERVICING S...

Page 4: ...earn about your equipment and its proper maintenance This is not a comprehensive technical service manual Nor will it make the reader into an expert mechanic Its aim is to aid you in maintaining your...

Page 5: ...ng adjustments Operate engines in properly ventilated areas Keep trash and other objects away from engine Escaping fluids under pressure can penetrate your skin Use a piece of cardboard or wood not yo...

Page 6: ...cations 16 Oil Filter 17 Oil Drain 18 Generator Set Plate 19 Control Panel Plug in 20 Fuel Lift Pump 21 Heat Exchanger End Cap 22 Coolant Fill Figure 1 and 2 M843NW2 9 Belt Guard 10 Injection Pump 11...

Page 7: ...it will return to RUN position To stop the engine hold the switch in the STOP position until the engine has completely stopped NOTE The rocker switch is used on Series 1 panels only and has a light th...

Page 8: ...Bypass Preheat switch in the ON position for 10 to 20 seconds before starting a cold engine Holding the switch too long can burn out the glow plugs This step is not necessary if the engine is already...

Page 9: ...mperature rises above 205 F 96 C on Marine units Repeat troubleshooting 3 If shutdown is activated and the temperature gauge shows temperature within normal temperature range a Check the engine crankc...

Page 10: ...necessary 4 More often if necessary 5 After first 50 hours then after 100 hours then at every 250 hours Servicing Schedule Chart SERVICE 50 250 500 1000 2500 POINT PAGE OPERATION DAILY Hours Hours Ho...

Page 11: ...OM843NW2 10 09 11 Service Record Notes...

Page 12: ...ration change oil every 100 hours or six weeks whichever comes first 4 Change oil at the end of each season and the begin ning of each season 5 Change oil when engine is warm 6 Dispose of waste oil in...

Page 13: ...learance after 1000 hours or as needed 2 Valve adjustments should be done after the cylinder head bolts have been re tightened Engine should be cold and NOT running 3 Watch the valves while turning th...

Page 14: ...he end of each day s operation This will reduce condensation and possible biological contamination d If biological contamination is detected or suspected contact your dealer for assistance SP7 9 FUEL...

Page 15: ...ystem 1 The fuel system is self bleeding However any system may need manual bleeding when a A new fuel filter is installed b The engine has run out of fuel c The fuel lines injection pump or any other...

Page 16: ...delivery lines Figure 12 Cover lines inlets and injection pump outlets Figure 14 Remove return line Figure 15 Unscrew injector Figure 16 Remove and replace copper sealing washer Figure 17 Reinstall in...

Page 17: ...Install delivery lines Leave loose at injectors for bleeding e Crank engine to fill lines Tighten lines at injectors to 11 18 ft lbs Start engine and check for leaks using a piece of paper or cardboa...

Page 18: ...pieces of failed impeller NOTE Place some kind of protection under the screwdrivers in order not to damage the pump housing If the impeller has broken into pieces remove front heat exchanger end cover...

Page 19: ...ufacturer charging and booster instructions SP 18 19 BATTERY CARE 1 Check electrolyte level daily Add distilled water to manufacturer s recommended level 2 Batteries cables and cable terminals should...

Page 20: ...plug connection Low battery output Check specific gravity of each battery Check electrolyte level of each battery Defective electrical system Repair or replace ground wire Starter Cranks Slowly Low b...

Page 21: ...Runs Irregularly Below normal engine temperature Remove and check thermostat or Stalls Frequently Clogged primary Clean or replace filter element fuel filter element Clogged secondary Replace seconda...

Page 22: ...ystem Defective thermostat Remove and check thermostat Defective temperature gauge Check water temperature with thermometer and replace gauge if necessary Water pump impeller worn broken Check impelle...

Page 23: ...proper level Improper type of oil Drain and fill crankcase with correct oil Partially plugged oil filter Replace filter Check bearings oil pump and relief valve for wear High Oil Consumption Break in...