2.7
FRONTIER CYLINDER TABLE
3.0
ROUTINE CHECKS
3.1
UNPACKING
Open the storage case or shipping container. Observe the relative position and placement of the
various components for future re-packing. Remove SCBA from the container and place on a clean
dry surface. Remove facepiece from protective bag.
3.2
INVENTORY AND EXAMINATION
Examine unit for physical condition and appearance of all components. Be sure the following major
components are included:
•
Facepiece or Hood
•
Backframe and Harness Assembly
•
Cylinder and Valve Assembly
•
Options ordered with unit
3.3
ROUTINE CHECKS AND INSPECTIONS
The following procedure shall be used for incoming and daily inspection of the apparatus. An SCBA
not routinely used, but kept for emergency use, shall be inspected at least monthly. All other appara-
tus shall additionally be inspected after each use.
10
024.037.00
910301LP
2216
Aluminum
1287 liters
30 min.
20.5 lbs.
6.9 in.
5 years
45 cu. ft.
024.035.00 910302LP 2216 Hoop
Wrapped 1301
liters
Aluminum
45.5 cu. ft.
30 min.
16.0. lbs.
6.9 in.
3 years
124001
910303LP
2216
Full Wrapped
1301 liters
30 min.
10.4 lbs.
6.9 in.
5 years
Carbon
45.5
cu.
ft.
024.098.00
910302HP
4500
Hoop Wrapped
1287 liters
30 min.
15.9 lbs.
5.5 in.
3 years
Aluminum
45
cu.
ft.
124002
910303HP
4500
Full Wrapped
1287 liters
30 min.
11.0 lbs.
5.4 in.
5 years
Carbon
45
cu.
ft.
124003
910453HP
4500
Full Wrapped
1887 liters
45 min.
14.8 lbs.
6.8 in.
5 years
Carbon
66
cu.
ft.
124004
910603HP
4500
Full Wrapped
2516 liters
60 min.
19.2 lbs.
7.1 in.
5 years
Carbon
88
cu.
ft.
North
Catalog
Number
Part
Number
Pressure
PSIG
Material
Free
Air
Capacity
NIOSH
Rated
Duration
@ 40 lpm
Cylinder
& Valve
Charged
Weight
Cylinder
Diameter
Hydrostatic
Interval
The apparatus must not be used until the following tests have been successfully completed. Any
discrepancy noted during the pre-use check and inspection shall be corrected only by authorized
personnel prior to the use of the apparatus.
WARNING
Summary of Contents for FRONTIER Series
Page 27: ...27 ...