background image

2.3 POSSIBLE PROBLEM…...………………………………………………………………………………… 

Even if the appliance is used correctly, some problems may arise for various reasons. The table that 
follows mentions some possible problems and some possible causes. 

In case of problem we control first if the electrical supply to the machine is right or not.                                    

 

POSSIBLE PROBLEM  

POSSIBLE CAUSES 

Machine is not operating 

Drop of main voltage.   

 

Heating element is not operating 

Check  if  there  is  damage    to  1)the  heating 
element  2)the  edge  of  supply  cord  connected 
with  heating  element.  3)  the  contactor  of  switch 
4) the switch  

Motor is not operating     

Check  if  there  is  damages  to  1)switch  on-off  
2)the  motor  coil  or  gear.  3)  fat  grouping  to  the 
axis of rotation. 

 
 
 
2.3 REPLACEMENT OF ELECTRICAL ELEMENTS............................................................................. 

 
To  replace  heating  elements,  switches  and  indicating  lamps  disconnect  the  appliance  from  power 
supply  then  remove  the  back  cover  of  the  appliance.  Release  heating  elements,  switches  and 
indicating lamps and replace.  
Remount the rear plate. 
 
 

CUT OFF THE POWER SUPPLY BEFORE COVER REMOVAL.  
 
 
2.4 TRAINING......................................................................................................................................... 

 
The personnel who are to install and connect the appliance must train the users appropriately so that 
they can handle the operation and safety measures of the appliance.  
 
 

ATTENTION !!!

 

 

  Check that main voltage in your working area is suitable for the settings on the label and that the 

appliance is properly earthed. 

 

  Before any service activity takes place or any parts are replaced on the appliance, make sure that 

pains supply is turned off. 

 
 

THE  MANUFACTURER  CANNOT  BE  HELD  RESPONSIBLE  FOR  ACCIDENTS  AND  DAMAGE 
CAUSED  TO  PERSONS,  ANIMALS  OR  PROPERTY  DUE  TO  NONCOMPLIANCE  WITH  THESE 
INSTRUCTIONS.  
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DKE6

Page 1: ... requirements of E E C 73 23 CEE EN 60335 1 02 EN 60335 2 48 03 SOTIRIOS D PRODANAS PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANTS PATISSERIES SNACK BAR OFFICE FACTORY 14km National road Thessaloniki Serron Liti P C 545 00 TEL FAX 30 3940 72770 73185 73184 P O BOX 400 70 P C 560 00 www north gr e mail northgas spark net gr ...

Page 2: ...30 920 MKDKE8 480 630 1115 DKE6 480 630 920 DKE8 480 630 1110 Electrical Supply MKDKE6 230V AC 400V 3N AC 50Hz MKDKE8 230V AC 400V 3N AC 50Hz DKE6 DKE8 230V AC 400V 3N AC 50Hz IP Grating ΙP 20 Appliance s Safety Complies to ΕΝ 60335 1 and 60335 2 42 requirements CE marking Power MODEL POWER IN TOTAL MKDKE6 4 200 Watt MKDKE8 5 600 Watt DKE6 4 200 Watt DKE8 5 600 Watt ...

Page 3: ... x 700 Watt DKE8 MKDKE8 8 x 700 Watt Spit s motor 12 Watt Fire resistan wiring Terminals fasteners Spit s start up switch with indicating lamp Four position knobs 0 1 2 3 one for every pair of heating elements MKDKE6 3 pcs DKE8 MKDKE8 4pcs Gland for supply cord Earth terminal Potential equivalent terminal marked Ρ Α Six polar polyamide connection for supply cord ...

Page 4: ...ngruence or if in doubt do not connect the apparatus Ask for the equipment to be checked by specialized personnel NORTH Gyros grills equipment are commercial grade appliances and should there for be used by personnel who are specially trained in their use All procedures concerning installation and connection of the appliance must be carried out exclusively by specialized technicians according to s...

Page 5: ...SSEMBLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 6: ...he appliance Enter a suitable supply cord through the gland Depending on the available power supply connect the cables a Single phase power supply MKDKE6 MKDKE8 DKE6 DKE8 Remove the provided bridges and short circuit L1 L2 and L3 Connect the phase to L1 or L2 or L3 the neutral to Ν1 or Ν2 and the earth to earth terminal b Three Phase power Supply MKDKE6 MKDKE8 DKE6 DKE8 Connect the phases to L1 L2...

Page 7: ...ICAL ELEMENTS To replace heating elements switches and indicating lamps disconnect the appliance from power supply then remove the back cover of the appliance Release heating elements switches and indicating lamps and replace Remount the rear plate CUT OFF THE POWER SUPPLY BEFORE COVER REMOVAL 2 4 TRAINING The personnel who are to install and connect the appliance must train the users appropriatel...

Page 8: ...UIPMENT ALL ASSEMBLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 9: ... and spices you have already prepared Secure the spit on the lower base by placing the arm in the appropriate support position Secure the top end of the spit in the appropriate position by locking the safety key Now the Gyros grill appliance is ready to operate All you have to do is set the desired heating element to spit distance about 10 cm and start the rotation motor by pressing switch 3 3 CLE...

Reviews: