North Star NSDW500 Installation And Operation Manual Download Page 5

5

Installation Steps

Step 2 - Make Hole For Filtered Water Faucet (not included)

Step 3 - Install Faucet (not included - North Star faucet shown)

IMPORTANT:

To avoid damaging the sink, consult a qualified plumber or installer for drilling procedures

in porcelain or stainless steel. Special drill bits are made for this.
1. Select one of the following places to install the faucet. Be sure there's room underneath so you can

make the needed connections.

In an existing sink spray attachment hole.

Drill a hole in the sink top.

Drill a hole in the countertop next to the sink.

2. If drilling is needed make a 1-1/4" dia. (minimum) hole for the faucet.

Fig. 3

hole in sink

or countertop

tubing adaptor, 

7/16-24 thd. to 3/8” Q.C.

faucet

base

o-ring

slotted

washer

spacer

lock washer

hex nut

3/8” tubing from

water filter outlet

Summary of Contents for NSDW500

Page 1: ...ned Engineered Assembled in the U S A How to install operate and maintain your Undersink Drinking Water Filter System Model NSDW500 If you have any questions or concerns when installing operating or m...

Page 2: ...on disinfected waters that may contain filterable cysts q All plumbing should be done in accordance with local codes and requirements In Massachusetts plumbing code 248 CMR 3 00 and 10 00 shall be ad...

Page 3: ...c drill and 1 1 4 drill bit if mounting hole is needed for the faucet IMPORTANT To avoid damaging the sink consult a qualified plumber or installer for drilling procedures in porcelain or stainless st...

Page 4: ...t s to relieve pressure 2 Disconnect the existing cold water line from the water shutoff valve 3 Make sure that the water supply fitting s gasket is inside the female threaded portion of the fitting 4...

Page 5: ...e for this 1 Select one of the following places to install the faucet Be sure there s room underneath so you can make the needed connections In an existing sink spray attachment hole Drill a hole in t...

Page 6: ...ilter system outlet Figure 1 Tubing Connection all push in fitting locations This system includes push in fittings for quick tubing connections If working with the fittings do the fol lowing Connect T...

Page 7: ...NSDW500 with replacement element pack 7358195 conforms to NSF ANSI 42 and 53 for the specific performance claims as verified and substanti ated by test data The rated capacity for this system is 270...

Page 8: ...8 Exploded View 8 1 2 3 4 3 6 5 7...

Page 9: ...ounting Hardware Kit includes 2 ea of Key Nos 6 7 6 Hanger Washer 2 req d 7 Screw 2 req d 201 8404054 Owner s Manual OPTIONAL ITEMS not included 8 WHEFCHR Faucet Chrome WHEFSAT Faucet Brushed Nickel P...

Page 10: ...rsink Drinking Water Filter System is operated at water pressures not exceeding 100 psi and at water temperatures not exceeding 100 F provided further that the Undersink Drinking Water Filter System i...

Page 11: ...ed tap water at a flow rate of 0 5 gpm 1 9 L min pH of 7 5 0 5 pres sure of 60 psig and temperature of 68 5 F Installation Requirements Pressure Range 30 100 psig 207 689 kPa Temperature Range 40 100...

Page 12: ...ide EDB 44 0 024 99 0 05 Haloacetonitriles HAN NA Bromochloroacetonitrile 22 0 55 98 NA Dibromoacetonitrile 24 0 65 98 NA Dichloroacetonitrile 9 6 0 25 98 NA Trichloroacetonitrile 15 0 35 98 NA Contam...