Limited Warranty 

 

                      

44

 

                        

 

 

Dear Valued Customer: 

 

The  NorthStar  Product  you  just  purchased  is  built  with  the  finest  material  and  craftsmanship.    Use  this  product  properly  and 
enjoy the benefits from its high performance.  By purchasing a NorthStar product, you show a desire for quality and durability.  
Like all mechanical equipment this unit requires a due amount of care.  Treat this unit like the high quality piece of machinery it 
is.    Neglect  and  improper  handling  may  impair  its  performance.    Please  thoroughly  read  the  instructions  and  understand  the 
operation before using your product.  Always contact NorthStar Product Support at 1-800-270-0810 prior to having any service 
or  warranty  work  performed,  as  some services  performed  by  parties  other  than  NorthStar  approved  service  centers  may  void 
this  warranty.    This  warranty  is  in  lieu  of  any  other  warranty  expressed  or  implied  and  NorthStar  assumes  no  other 
responsibility or liability outside that expressed within this warranty.

 

Limited Warranty 

 

NorthStar shall warranty any

 

piece of equipment manufactured, or parts of equipment manufactured, to be free from defects in 

material or workmanship for a period of: 

 

NorthStar Warranty 
Item # 

Consumer Warranty Period 

Commercial Warranty Period 

165956, 165955 

4 years from date of purchase by user 

2 years from date of purchase by user  

 

Engine Warranty 
Item # 

Consumer Warranty Period 

Commercial Warranty Period 

165956, 165955 

3 years from date of purchase by user 

3 years from date of purchase by user  

 

“Consumer use” means personal residential household use by a consumer. “Commercial use” means all other uses, including 
use for commercial, income producing or rental purposes or when purchased by a business. 

 

This  warranty  applies  to  the  original  purchaser  of  the  equipment  (verification  of  purchase,  in  the  form  of  a  receipt,  is  the 
responsibility  of  the  buyer),  is  non-transferable,  and  covers  parts  and  labor.    Parts  will  be  replaced  or  repaired  at  no  charge, 
except  when  the  equipment  has  failed  due  to  lack  of  proper  maintenance.    If  a  part  is  no  longer  available,  the  part  may  be 
replaced  with  a similar  part  of  equal  function.    Any  misuse,  abuse,  alteration  or  improper  installation  or  operations  will  void 
warranty.  Determining whether a part is to be replaced or repaired is the sole decision of NorthStar.  NorthStar will not provide 
for replacement of complete products due to defective parts.  Any costs incurred due to replacement or repair of items outside 
of a NorthStar approved facility is the responsibility of the buyer and not covered under warranty. Transportation costs to and 
from service center is the responsibility of the customer.   

 

In addition to the normal warranty, NorthStar shall warrant any normal wear item from defects in material or workmanship for a 
period of 90 days from the date of purchase by user.  Normal wear items include, but are not limited to, filter elements. 

 

This  warranty  specifically  excludes  the following;  failure  of  parts  due  to  damage  caused  by  accident,  fire,  flood,  windstorm, 
acts of God, applications not approved by NorthStar in writing, corrosion caused by chemicals, use of replacement parts which  
do not conform to manufacturer’s specifications, damage to accessory parts such as starting batteries

damage related to rodent 

and/or insect infestation and damage caused by vandalism.  Additional exclusions: loss of running time, inconvenience, loss of 
income, or loss of use, including any implied warranty of merchantability of fitness for a specific use.  Also, Outdoor Power 
Equipment needs periodic parts and service to perform well, and this warranty does not cover instances when normal use has 
exhausted the life of a component or the engine.   

 

This warranty does not cover any personal injury or damage to surrounding property caused  by failure of any part. Repair or 
replacement of parts does not extend the warranty period. 

 

The  engine  warranty  is  covered  under  the  terms  and  conditions  as  outlined  by  the  engine  manufactures  warranty  contained 
herein  and  is  the  sole  responsibility  of  the  engine  manufacture.    Normal  engine  maintenance  such  as  spark  plugs,  air  filters,  
adjustments, fuel system cleaning and obstruction due to build up is not covered by this NorthStar warranty.   

 

Please fill in the following information and have it on hand when you call in on a warranty claim. 

 

 
Customer Number: ______________________________________________________________ 
 
Date of Purchase: _______________________________________________________________ 
 
NorthStar Serial Number: _________________________________________________________ 
 
Item Number: __________________________________________________________________ 

Summary of Contents for M165955A

Page 1: ...or is properly grounded Use only UL listed outdoor rated grounded extension cords of proper size NEVER plug the generator directly into a wall outlet ANY connection to a building s electrical system M...

Page 2: ...Hazard Signal Word Definitions 2...

Page 3: ...t up as a PORTABLE or BUILDING BACK UP Power Source 16 5 Selecting a Suitable Site 19 6 Grounding the Generator 22 7 Battery Installation 23 Operation 1 General Safety Rules for Operation 24 2 Prepari...

Page 4: ...rements for natural gas and propane See the Specifications section of this manual with regard to specific gas flow and pressure requirements In addition note the following Natural gas The standard del...

Page 5: ...e engine Owner s Manual furnished with the generator NorthStar is constantly improving its products The specifications outlined herein are subject to change without prior notice or obligation The purc...

Page 6: ...3 Hertz Hz Voltage Regulation 110 129V 110 129V Power Factor 1 0 p f 1 0 p f Engine Honda GX630 Honda GX690 Engine Speed 3390 3798 RPM 3390 3798 RPM Fuel Type LP NG LP NG Pressure Range LP NG 7 11 in...

Page 7: ...austic acid and explosive gases can cause blindness or severe burns NO smoking sparks or flames NEVER touch both battery terminals at the same time with your hand or any non insulated tools FLUSH imme...

Page 8: ...f Description Ref Description 1 Air Cleaner 7 Generator Head 2 Engine Key Switch 8 Fuel Inlet 3 Oil Drain Plug 9 Vibration Isolation Mount 4 Oil Fill Port 10 LP NG Regulator Assembly Kit 5 Battery not...

Page 9: ...ad The electricity producing part of the generator Reference 8 Fuel Inlet A connection point to hook up the fuel supply Reference 9 Vibration Isolation Mount The engine and generator are mounted on ru...

Page 10: ...wattage The running and starting wattage requirements are often listed on a device s nameplate If wattage is not given on the device s nameplate the wattage may be calculated by multiplying the namepl...

Page 11: ...Printer 950 Lights Ten 75 Watt light bulbs 750 Microwave Oven 1000W 1000 Milk Cooler 1100 1800 Milker Vacuum Pump 2 HP 1000 2300 Miter Saw 10 1650 2400 Oscillating Fan 200 400 Portable Heater Kerosene...

Page 12: ...ces on your list This total must be lower than the continuous output rating of your generator Example Device to be Powered Greater of Starting Running Wattage Light Bulbs 10 75 watt 750 W Refrigerator...

Page 13: ...erator 6 Grounding 7 Battery installation Each of these steps is discussed in detail below 1 Unpacking Delivery Inspection You should inspect the generator immediately after you receive delivery See t...

Page 14: ...propane WARNING You must have the fuel line system installed by a certified gas technician for NG or LP NG LP Regulator Assembly Kit Set Up Regulator for Intended Gas Usage LP or NG Fuel selection is...

Page 15: ...ied and installed by your gas utility technician at the time of fuel system hook up o If your standard delivery pressure is lower than 4 6 ounces per square inch 7 11 water column you will need change...

Page 16: ...n below CAUTION Regardless of whether you use your generator as a back up power source connected to a building or as a portable power source you must not overload the generator Overloading may cause s...

Page 17: ...ous section of this manual entitled Power Load Planning Management for more information on load application and selection Using as a Portable Power Source When using the generator as a portable power...

Page 18: ...ver exceed the amperage rating of an outlet 2 Extension cords may be used to power devices that are located at a distance from the generator However use only UL listed outdoor rated grounded extension...

Page 19: ...ing your generator to avoid equipment damage and or injury and possible death from carbon monoxide poisoning electric shock or fire Choose a site that meets all of the criteria specified Dry level sur...

Page 20: ...ed flow of air to allow for proper cooling of engine and generator head WARNING Heat build up from inadequate ventilation can result in fire posing a serious risk to nearby persons and structures Situ...

Page 21: ...familiar with its use Away from dust dirt Do not use the generator in extremely dusty or dirty conditions Excessive dust and dirt can cause premature failure of the machine Hearing protection Generat...

Page 22: ...re from the clamp to the generator grounding post located on the electrical panel 4 Do not connect the generator grounding post to a water pipe or a ground used by a radio system If a licensed electri...

Page 23: ...eral battery safety rules and instructions listed below General Battery Safety Rules ALWAYS use eye protection when handling batteries NEVER smoke or work near sparks or other sources of ignition NEVE...

Page 24: ...t children operate Intended use Carefully read about and understand the intended use of this generator Do not use for other purposes as unforeseen hazards or equipment damage may result Under the infl...

Page 25: ...ly shut down the source of electrical power If this is not possible attempt to free the victim from the live conductor Avoid direct contact with victim Use a nonconducting implement such as a dry rope...

Page 26: ...uctions WARNING Burn hazard Never open oil port while engine is running Hot oil can spray over face and body Notes o Low oil shutdown feature prevents the generator from starting without sufficient oi...

Page 27: ...oving the generator and on a regular basis thereafter This method will help you detect small leaks b Also beware of gas odor Both LP and NG have an odorant added rotten egg sulfur smell that will aid...

Page 28: ...al WARNING Never open oil port while engine is running Hot oil can spray over face and body 4 Checking Generator Output Although the speed of the engine was carefully adjusted at the factory so that t...

Page 29: ...you are using the generator o As a portable power source o Connected to a building as a back up power source WARNING Do not overload generator Make sure that combined starting and running loads do no...

Page 30: ...3 If applicable shut off natural gas line valve Cool engine before storing Let engine cool for at least five minutes before storing A hot engine can be a fire hazard Choose a storage location Store t...

Page 31: ...working condition Prepare engine for long term storage if needed If you will not be able to exercise the generator regularly you must prepare the engine for long term storage to prevent gum deposits...

Page 32: ...safety glasses touch opposite terminals of the capacitor together with the tip of the screwdriver If there is stored charge in the capacitor a spark will be generated thereby discharging the capacitor...

Page 33: ...acturer s service instructions Replace if damaged Keep generator clean Keep generator clean If dust or debris accumulates on the generator clean the generator with a damp cloth or soft bristle brush D...

Page 34: ...qualified technician for adjustment Generator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Power Load Planning Mgt section of this manual b Make sure there is...

Page 35: ...and will also void the warranty Engine speed Never attempt to modify the engine speed setting The engine speed is preset at 3600 RPM for safe and optimal performance of the generator If speed needs a...

Page 36: ...ectrical codes If the generator is not isolated from the utility power system by such means generator output will back feed into the utility power grid This may result in injury or death to utility po...

Page 37: ...fter opening LP NG line supply smell for gas before starting engine If you do smell gas DO NOT start engine DO NOT light a match DO NOT flip on an electrical switch Exit area immediately and call gas...

Page 38: ...ing Safety After use Cool engine before storing Let engine cool for at least five minutes before storing A hot engine can be a fire hazard Shut off fuel supply Turn off propane tank valve or shut NG l...

Page 39: ...Generator Exploded View Rev A 39...

Page 40: ...racket gen head 1 All 19 787371 Upper iso mount bracket gen head 1 All 20 790845 Base 1 All 21 82377 1 4 20 x 7 HHSC gr g zinc 2 All 22 777164 Battery cable positive 1 All 23 785609 Battery stop 1 All...

Page 41: ...All 4 783053 NEMA 5 20 Receptacle 4 duplexes All 5 783091 30 AMP Circuit Breaker 2 All 6 783085 NEMA L5 30 Receptacle 1 All 7 31953 14 50 Receptacle 1 165956 8 783965 45 AMP Circuit Breaker 2 165956 9...

Page 42: ...Generator Head Exploded View Rev A 42...

Page 43: ...5 X 8 10mm Long 4 All 10 N A Rubber Cup 2 All 11 MA306403 Rear Bearing 1 All 12 MA306416 Nyloc Nut and Star Washer 1 All 13 MA30997 Grill 1 All 14 MA31065 Securing Stud Cap 1 All 15 MA30999 Fixing Rin...

Page 44: ...ether a part is to be replaced or repaired is the sole decision of NorthStar NorthStar will not provide for replacement of complete products due to defective parts Any costs incurred due to replacemen...

Page 45: ...45 This page left intentionally blank...

Page 46: ...46 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com...

Reviews: