Installation—26810011, 2681201, 99916, and 99917
12
Step One: Disconnect pump from power supply
Step Two: Disconnect inlet and outlet fittings from pump
Slide red QC clips open on the inlet and outlet ports of the pump.
Pull inlet and outlet fittings out of the pump.
Loosen hose clamp on outlet hose and remove outlet hose from outlet fitting.
Do not disconnect inlet hose from inlet fitting.
Step Three: Remove pump from sprayer
Remove four screws from pump mounting feet.
Remove pump from sprayer.
Step Four: Assemble fittings to regulator
Remove steel clips from outlet
and bypass ports of regulator.
Install QC x 3/8" HB fitting
(791569) into bypass port of
regulator. To insert quick connect
fittings, lubricate O-ring with
water and twist fitting while
inserting into pump port. Secure
with steel clip.
Thread 1/4" NPT plug (779859)
into 1/4" NPT port on front side
of regulator (the side of the
regulator with the “BYPASS”
label).
Thread pressure gauge into 1/4"
NPT port on back side of
regulator.
Install QC x 3/8" HB elbow
fitting (787212) into outlet port of
regulator. To insert quick connect
fittings, lubricate O-ring with
water and twist fitting while
inserting into pump port. Secure
with steel clip.
Step Five: Assemble regulator and fittings to pump
Install inlet port of the regulator into outlet port of the pump. Slide red QC clip
closed.
Turn regulator to orient knob toward the top of the pump.
Step Six: Drill hole in tank
Align the four circles on the supplied drill template sheet with the pump mounting
holes on the sprayer tank.
Using a 9/16" drill bit (not included) drill a hole through the top of the tank in the
position indicated by the appropriate X on the template.
Remove plastic debris from inside the tank (if chemicals have been used inside
the tank, refer to pg. 27 step 4 for personal decontamination after removing
debris).