SPECIFICATIONS 

 Item 

  Specification 

SIGNAL

 

 

Accuracy*

 

 No Load                      Load Error**

 

   

-F2 60 Hz to   1,000 Hz 

+/- 0.003

o

                     0.003

o

/VA 

      47 Hz to      <60 Hz 

+/- 0.025

o

                     0.003

o

/VA 

   

-F1 360 Hz to 2,000 Hz 

+/- 0.003

o

                      0.003

o

/VA 

   

                     10,000 Hz 

+/-0.015

o

                       0.015

o

/VA 

   

 

*Accuracy degrades as a linear function of 
frequency from 2 KHz to 10 KHz. 
**Balanced 80

o

 phase angle load. 

 

Resolution

 0.001

o

 

Velocity

 

CW or CCW from 0.5

o

 to 12,600

o

/second with 

0.01

o

 resolution 

 

Output Format

 

Synchro or Resolver, transformer isolated 

 

Output Voltage

 

Programmable for 11.8/26/90 V

L-L  

Output voltage 

tracks reference input. 

     Minimum L-L Load  Impedance 
 

Synchro (47-2000 Hz) 

Resolver (47-2000 Hz) 

Resolver (2-11 KHz) 

 
90 V

L-L

                      

26 V

L-L

               

11.8 V

L-L 

2025

 (3 VA)              ------               35

 (3 VA) 

2700

 (3 VA)          225 

 (3 VA)     35

 (3 VA) 

     ------                        ------               93

 (3 VA) 

REFERENCE

 

 Reference 

Input 

26 Vrms or 115 Vrms 

 Reference 

Frequency 

See Part Number (Option) Designation 

 Reference 

Current 

2.5 MA max. 

GENERAL

 

 Angle 

Range 

000.000

o

 to 359.999

o

 Magnitude 

Variation 

0.03% 

 Settling 

Time 

Less than 100 

µ

  Front Panel Controls 
            Power On/Off 
            Lamp Test 
            Remote 
            Input Angle Selector 
 
            Static/CW/CCW 
            Enter 
            Stop 
            Step 
 

 
Main Power Control 
All LED’s light at power-up 
Indicator lights when remote.  Press key to go to 
LOCAL 
6 lever switches, one per decade..  Sets static 
angles or velocity. 
Selects either discrete angle inputs or direction of 
rotation 
Starts rotation and changes angle in STEP mode. 
Stops rotation. 
In STATIC mode, output follows input changes 
immediately. In STEP mode, output will change 
only when ENTER switch is pressed. 

 

 

Summary of Contents for 5330

Page 1: ...frequency inputs Static angles and bi directional rotational velocities are fully programmable This instrument is an ideal replacement for older units that do not offer rotational capability The dynamic mode simulates a rotating component in either clockwise or counterclockwise direction Any rotational speed between 0 5 rps and 35 rps sec may be programmed These dynamic signals may be used to test...

Page 2: ... input Minimum L L Load Impedance Synchro 47 2000 Hz Resolver 47 2000 Hz Resolver 2 11 KHz 90 VL L 26 VL L 11 8 VL L 2025Ω 3 VA 35Ω 3 VA 2700Ω 3 VA 225 Ω 3 VA 35Ω 3 VA 93Ω 3 VA REFERENCE Reference Input 26 Vrms or 115 Vrms Reference Frequency See Part Number Option Designation Reference Current 2 5 MA max GENERAL Angle Range 000 000o to 359 999o Magnitude Variation 0 03 Settling Time Less than 100...

Page 3: ...ale 50 pin D Subminiature male The following tables show the pin designations for rear panel connectors J1 J2 and J3 J1 Pin Designations Pin Signal Name Function 1 2 3 4 5 6 7 8 9 SPARE SPARE S1 S2 REF LO REF HI 26V S4 S3 REF HI 115V Do Not Use Do Not Use Synchro Resolver Output Synchro Resolver Output Reference Low Input 26 V Reference Input Synchro Resolver Output Synchro Resolver Output 115 V R...

Page 4: ...Data Not Data Accepted Interface Clear Service Request Attention Safety Ground Data I O 5 Data I O 6 Data I O 7 Data I O 8 Remote Enable Signal Ground NOTE J2 mating connector IEEE 488 Standard J3 Pin Designations Pi Signal Name Function 1 2 3 4 17 18 19 20 21 33 34 35 36 37 38 39 50 SPARE CASE GND SPARE S2 S4 REF LO SPARE S1 S3 SPARE REF HI 115V REF HI 26V SPARE Do Not Use Chassis Earth Ground Do...

Page 5: ...indicated selection made Note There may be a delay of several seconds between time that key is pressed and time indicator lights This delay is due to time required for internal calibration values to be calculated and stored STATIC CW CCW Operation Default mode of operation is STATIC In STATIC mode the output angle is equal to the value set on the ANGLE SELECTOR lever switches CW and CCW select dir...

Page 6: ...0 or the ILC Data Device Corp Model SIM 31200 The Model 5330 may be configured to emulate the interface language of these products Once configured the Model 5330 will power up with selected language emulation activated Language emulation option is set at the factory prior to shipment Standard MATE language may be temporarily activated with an IEEE 488 command string as shown in the Table below Lan...

Page 7: ...d Rear Views of Model 5330 North Atlantic Industries Inc 631 567 1100 631 567 1823 fax 04 23 02 5330A001 Rev B1 0 170 Wilbur Place Bohemia NY 11716 www naii com e mail sales naii com Cage Code OVGU1 Page 7 of 8 ...

Page 8: ...ting Mounts two units side by side in 19 inch rack 3 1 2 inch rack height 548557 Tandem Full Rack Mounting Mounts two units side by side in 19 inch rack increases rack height to 7 inches 787026 FEATURES AND OPTIONS The Model 5330 is available with 2 standard options as shown below 5330 F1 Frequency Range 360Hz to 10 KHz 5330 F2 Frequency Range 47Hz to 1 KHz Custom solutions can be made to meet the...

Page 9: ...30A001 Rev B1 0 170 Wilbur Place Bohemia NY 11716 www naii com e mail sales naii com Cage Code OVGU1 Page 9 of 8 Revision History Revision Change Made By Date Notes Approved A Lou Garofolo 4 23 02 New Release LG B1 0 Robert Skrepek 9 21 04 Released in support of ECO E39993 ...

Reviews: