1. It is recommend to used a 20lbs LP-gas cylinder.
2. The LP-gas supply cylinder to be used must be constructed and marked in accordance with the
specification for LP-gas cylinders of the U.S. Department of Transportation (DOT) or the Standard
for Cylinders, Spheres and Tubes for the Transportation of Drangerour Goods CAN/CSA-B339
3. The gas must be turned off if the supply cylinder is not in use.
4. The pressure regulator and hose assembly supplied with the appliance must be used.
Replacement pressure regulators and hose assemblies must be those specified by the appliance
manufacturer.
5. The cylinder supply system must be arranged for vapor withdrawal.
6. It must include a collar to protect the cylinder valve.
7. Do not store a spare LP-gas cylinder under or near this appliance and never fill the cylinder beyond
80 percent full, otherwise, a fire causing death or serious injury may occur.
8. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of
dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps
or plugs may result in leakage of propane.
( After assembly is complete, check for gas leaks before lighting.)
FOR YOUR SAFETY
•
A leak test must be repeated each time the LP tank is connected or reconnected.
•
Do not smoke during leak test.
•
Do not use an open flame to check for gas leaks.
•
The cooker must be leak tested outdoors in a well-ventilated area, away from ignition sources such as gas
fire or electrical appliances. During the leak test, keep the cooker away from open flames or sparks.
TO TEST FOR A LEAK
1. Close the regulator valve. This shuts off the flow of gas from the regulator to the burner.
2. Be sure regulator is tightly connected to LP tank.
3. Open LP cylinder valve by 1/4 turn. This allows gas through the regulator. If you hear a rushing sound, turn
the gas off immediately. There is a major leak at the connection. Correct before proceeding.
4. Splash on a soapy liquid (ex. dishwashing liquid and water) on the connections around the regulator and POL-
cylinder connection.(figure# M) If “growing” bubbles appear, there is a leak. Close LP tank valve immediately.
Retighten connections and repeat the leak test procedures. DO NOT use the cooker if any leak can not be
stopped. Call
1-
866-626-4745
for replacement of hoses.
5.
Always close the LP tank valve after performing a leak test by turning the hand wheel clockwise.
LEAK TESTING
(Figure M)
Maintain a distance of
2.5ft (0.76M) between