7
-Replace oil with SAE 10W30 or
SAE 10W20 non detergent oil
(300ML)
-Drain crankcase and fill to
proper level
-Air pressure regulated too high -
Replace filter
-Improper oil viscosity
-Too much oil in crankcase
-Compressor overheated
-Restricted air filter
Oil discharge in air
-Check for proper adjustment
and if problem persists, replace
pressure switch
-Defective pressure switch or improper
adjustment
Safety valve releasing
-Check valve manually by pulling
upwards on ring. If condition
persists replace valve
-Clean or replace as necessary -
Replace check valve
-Air leak in safety valve
-Restricted air filter
-Defective check valve
Low pressure
-Check voltage, eliminate
extension cord or reset
-Check wiring connections
-Press the reset button or wait for
automatic reset (15 minutes)
-Fuse blown or circuit breaker tripped -
Loose electrical connections -
Overheated motor
Not starting
Corrective Action
Possible Cause(s)
Symptom