NT5D33 and NTRB34 Line-side E1 Interface Cards
Page 187 of 290
Line cards
Description
Figure 48
Test Carrier (T) screen
Tests can be performed once, for one through 98 minutes, or continuously
(selected by entering 99 minutes) until a
Stop Test
command is entered.
Tests will continue for the duration specified even if a failure occurs, and will
terminate at the end of the time period or when a
Stop Test
command is
issued. Only this command will stop a test with a duration selection of 99,
however the
STOP
command can terminate a test set to any duration from
one to 99. After entering the test number selection, a prompt similar to
Figure 49 will appear:
Figure 49
Test parameters screen
Before a test is run, be sure to verify that the card is disabled since the tests
will interfere with calls currently in process.
During a test, if an invalid word is received, this is recorded via a failure peg
counter. The peg counter has a limit of 65,000. At the end of the test, the Test
Results message will indicate how many failures, if any, occurred during the
test.
Table 47 shows which test to run for the associated equipment:
Test 1: Local Loopback Test
Test 2: External Loopback Test
Test 3: Network Loopback Test
(1,2,3 or S to cancel):
Enter Duration of Test (1-98 Mins, 0 = Once, 99 = Forever)
Test will interfere with traffic. Hit Q to quit or any Key to Continue
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......