background image

14

 

 FastRAD Installation Guide

Programming 
Alarm 
Reporting

The alarm programming session allows you to program the 
FastRAD to report alarms to the telephone number of a 
dedicated alarm center, such as a printer or terminal.

Before you begin an alarm programming session, make sure 
the display shows 

RAD Admin

.

If you do not have this display on the Norstar telephone, follow 
the steps listed in Starting a Programming Session.

To program the FastRAD Alarm Reports:

1.

Press

 ALARM

.

The display shows:

2.

Press

 CHNG 

to turn automatic alarm reporting on.

The display shows:

3.

Press 

NEXT

.

The display shows:

4.

Press 

CHNG

.

The display shows:

5.

Enter the KSU line number the FastRAD uses for remote 
connections. Refer to the Programming Record for the 
correct line number.

6.

Press

 NEXT

.

The display shows:

7.

Press

 SHOW 

to see where the FASTRAD reports its alarms.

The display shows:

Auto-report: OFF
BACK      CHNG    NEXT

Auto-report: ON
BACK      CHNG    NEXT

Report line: 001
BACK      CHNG    NEXT

Report line:_
CLEAR       BKSP     OK

Alarm number 1
BACK      SHOW    NEXT

<Alarm number>
BACK      CHNG    NEXT

855601 Book : 855601 Guide  Page 14  Wednesday, October 29, 1997  4:06 PM

Summary of Contents for FastRad

Page 1: ...FastRAD Installation Guide...

Page 2: ......

Page 3: ...afety Instructions ii Canadian Regulations iii Industry Canada Notice iii US Regulations iv Federal Communication Commission FCC Notice iv Introduction 1 Before you start 3 Special check list 4 Requir...

Page 4: ...ii Table of Contents FastRAD Installation Guide Testing the FastRAD 20 Troubleshooting 21 Programming Record 22...

Page 5: ...g telephone lines The exclamation point within an equilateral triangle is intended to alert the user to the pres ence of important operating and maintenance servicing instructions in the literature ac...

Page 6: ...abused by persons walking on it 8 Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock 9 Never spill liquid of any kind on the product 10 To reduc...

Page 7: ...lephone lines and internal metallic water pipe system if present are connected together This precau tion may be particularly important in rural areas Repairs to certified equipment should be made by a...

Page 8: ...Reorient or relocate the receiving TV or radio antenna where this may be done safely To the extent possible move the telephone system and the radio or television farther away from each other or conne...

Page 9: ...causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Signaling Method The equipment allows signaling in DTMF tones I...

Page 10: ...vi FastRAD Regulations...

Page 11: ...ommunicate with a Key Service Unit KSU FastRAD also runs with Companion Diagnostics System CDS and Companion Manager The FastRAD is located on site near either the KSU or the PC receives calls from a...

Page 12: ...ew of remote connection Distribution block Norstar KSU At the remote site the external line is connected to the FastRAD through a KSU line The FastRAD and the modem are connected through the telephone...

Page 13: ...are provided in this guide Important Only one FastRAD can be connected to a KSU Environment check list The FastRAD installation area should be clean free of dust dry and well ventilated between 0 and...

Page 14: ...of tape or four tacks for mounting the template a list of programming parameters for the FastRAD a unique System identification ID number a unique password the Norstar ICS Remote Toolssoftware and do...

Page 15: ...tRAD Table 1 shows which pins are used to make a connection with the FastRAD Note The FastRAD modem supports V 32 V 32bis protocols only We recommend a baud rate of 9600 or greater be selected when co...

Page 16: ...he power connector of the FastRAD and the other end into the wall outlet See Figure 2 2 Check that the LED on the FastRAD unit is lit to confirm the power connection 3 Locate the distribution block 4...

Page 17: ...de panel of the FastRAD See Figure 2 7 Connect the other end to the RJ 11 teladapt jack to the KSU Make sure the cord is less than 800 m 2600 feet long Note A connection to the FastRAD DB 9 pin serial...

Page 18: ...FastRAD on the wall if it is only being used temporarily to program the KSU The FastRAD can be mounted either horizontally or vertically To mount the FastRAD on the wall 1 Attach the paper mounting t...

Page 19: ...the template show where the two screws are placed After the screws are in place remove the paper template Figure 4 Mounting the FastRAD 3 Place the two keyhole slots at the back of the FastRAD over th...

Page 20: ...remote access to the FastRAD is desired Table 2 Programming parameters and default values Programming Field Range Required Optional Default Password 8 to 10 digits Required none System ID Up to 10 di...

Page 21: ...gramming session is termi nated when you press incorrect buttons or when you make or answer a call Only on a DR2 KSU can you put the programming session on hold to make or answer a call If you need to...

Page 22: ...e recommend you assign a password the first time you start a programming session You must assign a pass word before you can perform remote access Write down your password keep it in a safe place and a...

Page 23: ...te If this is a first time installation we recommend the system ID number must be programmed to allow remote access If this is not a first time installation the display shows the last System ID entere...

Page 24: ...sion To program the FastRAD Alarm Reports 1 Press ALARM The display shows 2 Press CHNG to turn automatic alarm reporting on The display shows 3 Press NEXT The display shows 4 Press CHNG The display sh...

Page 25: ...press NEXT and go to step 14 12 Press CHNG The display shows 13 Enter the telephone number for Alarm 2 14 Press OK The display shows Note If you are using the default setting s press NEXT and go to s...

Page 26: ...connected to a slow de vice such as an old printer Selecting the Low setting limits the baud rate to less than 300 Selecting the Medium setting limits the baud rate to less than 1200 Selecting the Hig...

Page 27: ...ow unassisted access to the FastRAD Before you begin programming make sure the display shows RAD Admin If you do not have this display on the Norstar telephone follow the steps in Starting a Programmi...

Page 28: ...econds the FastRAD waits before answering an incoming data call The display shows 8 Enter the number of seconds you want the FastRAD to wait prior to answering an incoming data call This number must b...

Page 29: ...200 2400 4800 9600 or 19200 Note To use Norstar Manager in a direct connection the local baud rate must be set to 9600 baud 11 Press NEXT The display shows 12 Press to end programming The FastRAD prog...

Page 30: ...ork site refer to ICS Remote Tools User Guide for instructions about connecting to the RAD The test is passed when the remote or local PC establishes a connection with the KSU If the FastRAD is progra...

Page 31: ...is lit to confirm the power connection 4 Refer to the appropriate Norstar Installer Guide for further diagnostic tests Note If the wiring at the distribution block has been discon nected the FastRAD...

Page 32: ...ult is 001 Alarm Number 1 __________ Enter the telephone number of the device where the FastRAD reports alarms Alarm Number 2 __________ Enter the telephone number of a second device where the FastRAD...

Page 33: ...____ Enter the number of seconds the FastRAD waits before answer ing a call Enter a number between 6 to 60 The default is 18 Local Baud Rate 300 1200 2400 4800 9600 19200 Choose the baud rate the Fast...

Page 34: ...24 FastRAD Installation Guide...

Page 35: ...1 800 4NORTEL www nortel com norstar Norstar is a trademark of Nortel Networks Printed in Canada P0855601 Issue 05...

Reviews: