Install the NIU 5008 equipment associated with the CTR 38 GHz microwave
transceiver as follows:
1. Connect the CPI 9000 (power inserter) to -48 VDC power source.
2. Adjust voltage out of CPI 9000. It is adjustable from 17V to 21V,
depending on cable length and type.
3. Connect power inserter unit’s IF IN port (N-type connector) to the NIU’s
IF OUT N-type (bulkhead) connector as shown in Figure 1-2.
4. Connect CTR 38 GHz IF/PS cable to the CPI 9000 output (PS/IF) port
(N-type connector).
5. Connect CTR 38 GHz RX cable to NIU IF IN N-type (bulkhead)
connector.
6. Refer to Reunion NIU 5008 Network Interface Unit Installation Guide,
Release 1.2, 411- 1323 - 203, and the Network Engineering Package.
Figure 1-2
Block Diagram showing CTR 38 GHz indoor set-up with NIU 5008
NIU 5008
CMM
TX
RX
to CTR 38 GHz IF/PS
from CTR 38 GHz RX
CPI 9000
-48 DC
18 V
-48 VDC
CDM
DC In
IF In