Troubleshooting a failed automatic SEU Update
35
4
Ensure that the httpstraffic is allowed between the TPS DC and
the check point firewall PC.
--End--
Troubleshooting a failed upgrade
This section outlines the documented mechanism for reverting back to the
previous version of code if an upgrade fails. Downgrade is supported from
version 4.6.0 (1145 builds) to version 4.5.1.3.
CAUTION
Only upgrade-revert-upgrade is supported, not
upgrade-revert-upgrade-revert.
Procedure 23
Procedure steps
Step
Action
1
When an upgrade fails, enter the following command to revert
back to the previous code.
revert
2
Wait for the system to reboot completely.
3
Login to the Graphical User Interface (GUI). On the menu bar
choose Operation, Help and then About to check the reverted
software version.
--End--
Troubleshooting a failed automatic SEU Update
This section describes how to troubleshoot an SEU update when the auto
update feature is not working. The system responds with the following
output message:
An error message occurred while running task
Nortel TPS 4.7