31
Table 12. Blower Performance - 3.5 Ton
R104HD -X42K080C
80,000 BTUH, 34” CABINET, 11”X10” BLOWER W- 1 HP ECM MOTOR
230 VOLT OPERATION
SWITCH
SETTINGS
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1
2
3
4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
0
0
0
0
1347
53
1295
55
1242
57
1187
60
1131
63
1077
66
1023
70
970
74
916
78
1
0
0
0
1402
51
1353
53
1305
55
1252
57
1199
59
1147
62
1094
65
1039
69
984
72
0
1
0
0
1457
49
1412
50
1367
52
1317
54
1267
56
1216
59
1165
61
1109
64
1052
68
1
1
0
0
1517
47
1468
49
1420
50
1374
52
1328
54
1279
56
1229
58
1172
61
1115
64
0
0
1
0
1576
45
1524
47
1472
48
1431
50
1389
51
1341
53
1293
55
1236
58
1178
61
1
0
1
0
1625
44
1576
45
1528
47
1485
48
1442
49
1394
51
1346
53
1289
55
1233
58
0
1
1
0 1674
43
1629
44
1583
45
1539
46
1494
48
1446
49
1398
51
1343
53
1287
55
1
1
1
0
1721
41
1675
43
1629
44
1583
45
1538
46
1491
48
1445
49
1390
51
1336
53
0
0
0
1
1768
40
1721
41
1674
43
1628
44
1582
45
1537
46
1491
48
1438
50
1384
52
1
0
0
1
1807
39
1762
40
1717
42
1671
43
1626
44
1580
45
1534
46
1483
48
1433
50
0
1
0
1
1846
39
1803
40
1759
41
1715
42
1670
43
1623
44
1576
45
1529
47
1482
48
1
1
0
1
1889
38
1843
39
1798
40
1754
41
1710
42
1663
43
1617
44
1571
45
1526
47
0
0
1
1
1931
37
1884
38
1837
39
1793
40
1749
41
1703
42
1657
43
1613
44
1569
45
1
0
1
1
1970
36
1925
37
1881
38
1836
39
1792
40
1747
41
1703
42
1658
43
1614
44
0
1
1
1
2008
36
1967
36
1925
37
1880
38
1834
39
1791
40
1748
41
1704
42
1659
43
1
1
1
1
2038
35
1998
36
1957
36
1924
37
1891
38
1874
38
1857
38
1809
39
1760
41
208 VOLT OPERATION
SWITCH
SETTINGS
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1
2
3
4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
0
0
0
0
1308
55
1252
57
1196
60
1139
63
1082
66
1025
70
967
74
915
78
863
83
1
0
0
0
1363
52
1309
54
1255
57
1199
59
1143
62
1088
66
1033
69
979
73
926
77
0
1
0
0
1417
50
1366
52
1314
54
1259
57
1203
59
1151
62
1098
65
1043
68
988
72
1
1
0
0
1470
49
1418
50
1366
52
1315
54
1265
56
1212
59
1159
62
1102
65
1045
68
0
0
1
0
1523
47
1471
48
1418
50
1372
52
1326
54
1273
56
1220
58
1161
61
1102
65
1
0
1
0
1566
46
1515
47
1464
49
1417
50
1371
52
1321
54
1271
56
1211
59
1151
62
0
1
1
0 1608
44
1559
46
1509
48
1462
49
1415
50
1369
52
1322
54
1261
57
1200
59
1
1
1
0
1650
43
1602
45
1554
46
1508
47
1461
49
1411
51
1362
52
1303
55
1245
57
0
0
0
1
1691
42
1645
43
1599
45
1553
46
1507
47
1454
49
1401
51
1345
53
1289
55
1
0
0
1
1737
41
1691
42
1644
43
1599
45
1554
46
1503
47
1451
49
1396
51
1342
53
0
1
0
1
1783
40
1736
41
1689
42
1645
43
1601
45
1551
46
1501
47
1448
49
1394
51
1
1
0
1
1823
39
1776
40
1730
41
1684
42
1638
44
1589
45
1539
46
1488
48
1437
50
0
0
1
1
1862
38
1817
39
1771
40
1723
41
1675
43
1626
44
1577
45
1529
47
1480
48
1
0
1
1
1904
37
1857
38
1810
39
1763
40
1717
42
1672
43
1627
44
1599
45
1572
45
0
1
1
1
1946
37
1898
38
1849
39
1804
40
1758
41
1717
42
1676
43
1670
43
1664
43
1
1
1
1
1977
36
1936
37
1895
38
1878
38
1860
38
1809
39
1757
41
1709
42
1660
43
NOTES:
1. Factory settings are in bold. Use of any other switch setting may result in nuisance trips and should be verified for the application.
2. Temperature rises in tables are approximate. Actual temperature rises may vary.
3. Shaded areas are not recommended or approved for proper heating operation of equipment.
Heat rise: Btu/h (Input) = CFM * Δ T * 1.08
Δ T = (Btu/h * 0.95) / (CFM * 1.08)