37
18. Appendix B - Mode Table
CONSOLE OPERATING MODE
HOME MODE
AWAY MODE
(Overrides Night Mode)
NIGHT MODE
Repor
ts to Central Station
V
oice Announcement
Star
ts T
w
o-wa
y
A
udio
Repor
ts to Central Station
V
oice Announcement
Star
ts T
w
o-wa
y
A
udio
Repor
ts to Central Station
V
oice Announcement
Star
ts T
w
o-wa
y
A
udio
SYSTEM EVENT
Fire & CO Alarms
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
Fire & CO Supervisory
Timeout
[2]
✓
Yes
~
If Enabled
[8]
N/A
✓
Yes
✗
No
N/A
✓
Yes
✗
No
N/A
Fire & CO Sensor Low
Battery
[2]
✓
Yes
~
If Enabled
[8]
N/A
✓
Yes
✗
No
N/A
✓
Yes
✗
No
N/A
Console (
HELP
button) Alarm
✓
Yes
✓
Yes
~
If Enabled
✓
Yes
✓
Yes
~
If Enabled
✓
Yes
✓
Yes
~
If Enabled
Emergency Sensor Alarm
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
✓
Yes
✓
Yes
~
If Enabled
[6]
Emergency Sensor
Supervisory Timeout
[2]
~
If Enabled
~
If Enabled
[8]
N/A
✗
No
[1]
✗
No
[1]
N/A
~
If Enabled
✗
No
✗
No
Emergency Sensor Low
Battery
[2]
✓
Yes
~
If Enabled
[8]
N/A
✓
Yes
✗
No
[1]
N/A
✓
Yes
✗
No
N/A
Console Trouble
[2] & [5]
✓
Yes
~
If Enabled
[8] & [9]
N/A
✓
Yes
✗
No
N/A
✓
Yes
✗
No
N/A
Communication Status
(telephone/cell)
✗
No
✓
Yes
N/A
✗
No
✓
Yes
N/A
✗
No
✗
No
N/A
Module Status
N/A
✓
Yes
N/A
N/A
✗
No
N/A
N/A
✗
No
N/A
Activity Monitor
✓
Yes
✓
Yes
~
If Enabled
[7]
✗
No
✗
No
✗
No
✓
Yes
✓
Yes
~
If Enabled
[7]
Entering Mode
✓
Yes
From Away
Mode Only
[10]
N/A
✓
Yes
✓
Yes
N/A
From Away
Mode Only
From Away
Mode Only
N/A
Mode Table Notes:
• [1] Setting the Console in Away Mode clears all supervisory events for
emergency sensors only. Supervisory timers for Smoke detectors, CO
detectors, and activity monitor sensors are not affected; switching to Home
or Away Mode constitutes activity.
• [2] Supervisory events are reported by automatic status reports regardless
of the global
REPORT SUPERVISORY EVENTS
setting. Also, AC power
loss events are reported by automatic status reports regardless of the global
REPORT AC FAIL
setting. Both settings are on the Reporting Options tab.
• [3] Console supervisory faults are always reported, but not annunciated in
Away Mode and Night Mode.
• [4] To start a two-way audio session after a report is triggered by an
emergency alarm sensor, two-way audio must be globally enabled in
TWO-WAY AUDIO MODE
on the Reporting Options tab and enabled for
the sensor’s zone with the
TWO-WAY AUDIO
check box on the Sensors tab.
• [5] For activity sensors, two-way audio is enabled globally in
TWO-WAY
AUDIO MODE
on the Reporting Options tab regardless of the activity
sensor’s zone setting with the
TWO-WAY AUDIO
check box on the Sensors
tab.
• [6] To enable Console/sensor zone low battery and sensor zone supervision
annunciations,
ANNUNCIATE TROUBLE INDICATION
must be selected on
the Console tab.
• [7] To announce telephone line and AC power status,
ANNUNCIATE
PHONE-LINE/AC STATUS
must be selected on the Console tab.
• [8] The Console will only announce Home Mode when manually switched
from Away Mode using the
HOME
button.