background image

13

10.3 The  Menu Bar

The menu bar provides access to each of the programs sub-menus. The 
icons below the menu bar are used to open, save, and print User Account 
Templates and perform various actions with the PERS-4200X Console.

Drop-down Menu Items and Icons

The sub-menus that can be accessed from the Menu Bar are:

File

NEW

Opens a blank Account Template. The common Console default values are 
already fi lled in.

OPEN

Loads a saved Account Template into the RA4200 workspace. Only one 
Account Template can be open at a time in the RA4200 workspace.

SAVE

Saves the open Account Template to the hard drive. A warning dialog will be 
displayed if the template will overwrite the existing fi le.

PRINT / PREVIEW

Opens the account information print preview window to allow printing of 
the active Account Template. Shows what will be printed on the screen with 
options to zoom in or print the document. Resulting printout is the entire 
content of the Account Template fi le and the Console’s event log in text 
format.

EXIT

Closes the RA4200 program. If the Account Template has changed, you will 
be asked if you want to save it.

Communication

CONNECT

Opens the Send/Receive window. Uses the telephone number and password 
from the open template. Sets up and starts a modem or COM port (local with 
USB) connection.

DISCONNECT

Terminates the connection between the RA4200 program and the 
PERS-4200X Console.

GET CONSOLE

Retrieves the Account Template from the PERS-4200X Console that is 
currently connected to the RA4200 program.

GET LOG

Retrieves the Event Log from the PERS-4200X Console that is currently 
connected to the RA4200 program.

SET CONSOLE

Sends the Account Template from the RA4200 program to the PERS-4200X 
Console that is currently connected.

CONSOLE TIME

Opens the Set Time window. This function can be used to set the date and 
time or get the date and time of the Console currently connected to the 
program. Daylight saving time can be enabled or disabled, and the start and 
end weeks of daylight saving time can be adjusted.

Tools

CLEAR EVENT LOG

Deletes the logged events from the connected PERS-4200X Console. It is 
recommended that the Dealer retain data from the event log for a period of 
two years.

TEST IP REPORTING

Sends a test IP message from the Console to the Central Station. Requires 
a modem or USB connection to the Console, and an Internet connection.

IMPORT OR EXPORT FILE VIEWER

For reading the content of an *.ra3 export fi le, or an *.ra5 / *.ra6 import fi le.

EXPORT FILE TO MANAGEMENT SERVER

Creates a confi guration export fi le to be sent to the Console using the 
Management Server. This feature requires an internet connection. This is an 
alternate way to change the Console confi guration. Think of the Management 
Server as being a mailbox (it does more). An export fi le has confi guration 
settings and is meant to be delivered to the PERS Console (as compared to 
an import fi le which has confi guration settings from the PERS and is meant 
to be delivered, the other way, to the RA4200 application). The Management 
Server serves as an in-between conduit.

 

NOTE: The export fi lename is the IP account number by default. 
This fi lename is used by the Management 

S

erver in sending a new 

confi guration to the PER

S

 Console (with the matching IP account 

number). To change the IP account number in the Console via an export 
fi le, do the following:

1. 

Change the the IP Account number fi eld in the template (to the new 
number).

2. 

Use the “Export” function, and when presented with a choice to use 
the default IP account number as the fi lename (this would be the new 
number) or to use an alternate fi lename, select alternate. Enter the old IP 
account number in the corresponding fi eld and proceed with the export 
function.

The Management Server will then update the PERS Console (still with the 
old IP account number), and change its (IP account) number to the new one.

RETRIEVE IMPORT FILE FROM MANAGEMENT SERVER

Retrieve data that have been sent to the Management Server (from the 
Console). These will be *.ra5 / *.ra6 import fi les. This function will move these 
import fi les from the Management Server to the local PC.

MERGE IMPORT (*.RA5 / *.RA6) or EXPORT (*.RA3) FILE

Merges data from an import fi le into a matching account template. All export, 
import fi les in the specifi ed folder will be merged into their corresponding 
account template fi les (with the matching IP account number). Merging an 
export fi le is allowed as an option. Reopen the appropriate account template 
(*.ra1) in RA4200 to view the latest merged info.

Toolbox

PANEL FIRMWARE UPDATE (DfuSe)

Launch the Console fi rmware update tool. This feature requires a USB 
connection. The Console also needs to be put in fi rmware update mode.

SELECT PERS CONSOLE TYPE

Select the PERS Console family. This will enable/disable the appropriate 
data fi elds.

AUTOMATIC STATUS REPORT RANDOMIZATION

Enable this feature to randomize the time of reporting. There’s an option here 
to set the desired range of time.

CHANGE PASSWORD

Select to change the password. The correct password is needed to enable 
saving the account template.

Help

CONTENT

Opens the help Contents search window. Used for accessing the RA4200 
program’s built-in help fi le. Function key F1 also accesses the help fi le.

ABOUT RA4200

Displays the version number of the RA4200 software.

Summary of Contents for Numera PERS-4200X Series

Page 1: ...INSTR INSTL PERS 4200X P N 10007317 B INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 TOLERANCE 125 SCALE 1 1 FOLDING ALBUM FOLD BINDING SADDLE STITCH www nortekcontrol com MHz 2GIG 345 PERS 4...

Page 2: ...cs equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment W E E E The separate collection and recycling of your waste electrical a...

Page 3: ...User Password 15 Provider Password 15 Mode After Disconnect 15 Transmission Supervision Interval 15 Emergency Siren 15 Voice Prompts 15 Annunciate Trouble Indication 16 Annunciate Status with Home Bu...

Page 4: ...detectors Wireless transmitters can also be configured as activity timer reset devices to verify activity at the User s location 1 1 Console Features Voice Prompts A built in digital voice synthesize...

Page 5: ...itters can be wired to a pushbutton or switch for manual activity monitoring As long as a signal is received from each activity sensor during a programmed activity time window an alarm will not be tri...

Page 6: ...lations where the activity timer will not be used a snap on button cover is supplied to hide the HOME button NOTE The HOME button cover cannot be easily removed once the cover is in place PERS 4200X C...

Page 7: ...LOCAL PROGRAMMING ONLY INSERT USB PLUG INTO PROGRAMMING COMPUTER USB PORT OPTION MODULES PLUG INTO CONSOLE CELLULAR TELEPHONE MODULE REMOTE SPEAKER MICROPHONE MODULE BE SURE TO SECURE MODULES WITH SCR...

Page 8: ...me controls are provided to customize the sound levels of the Console for the installation The Dealer or Installer should use their judgment and expertise in determining the appropriate volume level f...

Page 9: ...y The Console will start the Two way audio session if enabled IfTwo way audio is not enabled after the report is completed the Console will announce 0 Emergency reported 4 4 User Features Several feat...

Page 10: ...Programming Mode the Console is not operational and cannot receive or report alarms 5 4 Test Learn Mode Test Learn Mode is accessible using the TEST button on the Console This mode can be used to loca...

Page 11: ...ch account template file 6 2 RA4200 FAQ How does RA4200 connect to a Console RA4200 can connect to the Console two ways Remote connection over the telephone line using the computer s modem Local USB c...

Page 12: ...0 Software Installation The RA4200 remote access software is available on the Web at this link www nortekcontrol com downloads php The installation program will create a directory on your hard disk dr...

Page 13: ...the Modem in Windows Windows Control Panel can be used to test the modem and determine what COM port the modem is connected to 1 Open Windows Control Panel 2 Select PHONE AND MODEM 3 Click on the MOD...

Page 14: ...et Several other Console options and settings are also available in this tab The Console s time and date settings are displayed Sensors Displays the 16 wireless sensor zones of the PERS 4200X Console...

Page 15: ...export file to be sent to the Console using the Management Server This feature requires an internet connection This is an alternate way to change the Console configuration Think of the Management Ser...

Page 16: ...ammed information from an already programmed Console although the data on the Customer tab will be lost and have to be reentered 11 2 Customer Tab The Customer tab displays fill in fields for details...

Page 17: ...detectors These types of sensors are always set by the Console to require reception of a status signal at least once every 24 hours Select one of the six options for the supervision interval 12 hours...

Page 18: ...tion is NOT grayed out the Console can annunciate voice prompts in English or Spanish to guide the user during operation and guide the Dealer or Installer during programming The two resident languages...

Page 19: ...om a wireless sensor two options are available to control when the Console reports a low sensor battery Option 1 When a low battery signal is received from a sensor the Console will immediately report...

Page 20: ...ters in field units easier Select AUTO DETECT for a sensor zone to automatically detect if a wireless transmitter is sending status signals Once the Console detects status signals from a transmitter i...

Page 21: ...k option is selected the Two way audio setting will automatically adjust for the reporting method chosen PSTN or IP reporting PSTN Dialing Sequence The Console will make multiple attempts to make a co...

Page 22: ...have the Console speaker active during dialing PrimaryTelephone Number The primary telephone number is the number that will be dialed first in the dialing sequence The number can be up to 20 digits i...

Page 23: ...formed for cellular reporting Note that an appropriate mobile terminated voice service plan is needed to use this feature The Two Way Audio Mode must also be enabled for callback to work Event Account...

Page 24: ...ice plan for the device Dealers will also have to change the configuration of the Console to use the gprs02 motient net APN IP service field to support call back See the example of the typicalTelit m2...

Page 25: ...ode and announce FW Version and HW Version Press the HELP button while in Test Mode Console checks the presence of hardware if a Cellular Module is installed the Console announces Cellular module dete...

Page 26: ...only works with 2GIG fall detection sensors when used with the PERS 4200X Console that supports fall detection reporting The default setting enables fall detection reporting Un check to disable fall d...

Page 27: ...nnot be cancelled The default setting for dialing delay is OFF Two way Audio Mode The Console supports Two way audio communications with the User through the Console s speaker and microphone The defau...

Page 28: ...ENABLE box 2 Click the TEST REMINDER button 3 Select a Day of Month and Time for the monthly test message to occur 4 Click OK Test Reminder Operation When the programmed system test time occurs a rem...

Page 29: ...layed in the RA4200 connection status area 5 The modem will place a call to the Console wait a few rings then hang up This readies the Console to answer a call The modem will call the Console again th...

Page 30: ...date If daylight saving time is enabled verify the start and stop dates Press SET TIME to update the Console s date and time Press DONE 4 Press SET CONSOLE The template will be sent to the Console 5 P...

Page 31: ...0 Press nine to hang up 0 Press zero for main menu If selecting a new format the Console will announce over the telephone 0 Report format is reporting format press pound to accept or press star to ch...

Page 32: ...ber 2 Press and release the TEST button again The Console will announce 0 Ready to learn sensor Zone number 3 Activate the sensor to learn The Console will announce 0 Fire Activity Emergency Carbon Mo...

Page 33: ...unce 0 Fire Activity Emergency Carbon Monoxide sensor zone number full or low signal If the sensor tested has a low battery the Console will announce 0 Sensor low battery zone number 3 When finished p...

Page 34: ...remote access events are logged Remote access RA4200 sessions Console supervisory events AC power low battery phone trouble Sensor supervisory events supervision low battery NOTE Extended event loggin...

Page 35: ...he FILE menu select PRINT PREVIEW or on the toolbar click the PRINT icon 3 The Account Information print preview window will be displayed The preview shows the account template contents detailed on se...

Page 36: ...1 Click LEAVE DFU MODE The RA4200 will disconnect the Console and the Console will reset 12 Click QUIT to exit the DfuSe utility 13 Configure the Console with the RA4200 as required NOTE Should any pr...

Page 37: ...35 DfuSe Utility Connected to Console Firmware File Selection Verify and Target ID Selection Upgrading in Process DfuSe Device Warning Upgrade Complete...

Page 38: ...E LOW BATTERY 1 1384 XX 2 40 SENSOR FT FIRE SMOKE SUPERVISORY 1200 XX 2 40 SENSOR FS FIRE SMOKE SUPERVISORY RESTORE 3200 XX 2 40 SENSOR FQ CO ALARM GAS 1162 XX 2 10 SENSOR GA CO LOW BATTERY 1384 XX 2...

Page 39: ...the Console in Away Mode clears all supervisory events for emergency sensors only Supervisory timers for Smoke detectors CO detectors and activity monitor sensors are not affected switching to Home or...

Page 40: ...E CELL MODULE PRESENT Opening Port COM30 Initializing Com Port Sending password Login Success Get status data Console Type Standard Console Protocol Ver 5 Hardware Ver 0 Firmware Ver 2 4 0 Data Versio...

Page 41: ...NG IP REPORTING DELAY 0 or 15 Seconds IP REPORTING FORMATS SIA CID18 Extended CID58 Extended REMOTE PROGRAMMING PASSWORD 6 Digits REMOTE COMMUNICATIONS PASSWORD 4 Digits ACCOUNT NUMBER LENGTH FIBRO IP...

Page 42: ...a applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit ac...

Page 43: ...ment Server Timer 21 Menu bar 13 Mode after disconnect 15 Modem connection 27 Modem testing 11 Mode setting 25 Mode switch reporting 24 Mode switch reporting setting 24 Mode table 37 N Night mode 7 16...

Page 44: ...Copyright 2016 Nortek Security Control LLC 10007317 B...

Reviews: