SETTING CLOSED LIMIT POSITION

TRANSMITTER PROGRAMMING

With gate in the open position, (arm retracted) turn the 
control box ON/OFF switch to the off position. Press and 
hold the transmitter while sliding the ON/OFF switch to the 
ON position and you will hear a single or a series of beeps 
followed by a pause then a single beep. At that point release 
the transmitter button. This process may take 8 - 10 seconds.

Press and release the learned transmitter button; gate should 
start closing.  When the gate reaches the desired CLOSED 
position, press and release the transmitter button again.  
NOTE: If your gate stops and reverses before it fully closes, you 
may need to increase the stall force. (See 

page 10

)

Press and release the transmitter button again; gate should 
start opening.  Once the gate reaches the OPEN position, a 
single audible alarm will sound to indicate the limit is set.

Gate operator’s closed position is now set. Press and release 
transmitter to close gate for normal operation.

WARNING: 

Changes, modifications or adjustments not expressly approved by Nortek Security and Control, LLC could void the user’s 

authority to operate this equipment. There Are No User Serviceable Parts.

NOTICE:

 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 the FCC. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio 
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•  Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.

3

4

ON/OFF Switch

Replace and secure back cover of the opener remote.

Turn off control box. Press and hold a transmitter button while sliding 
the ON/OFF switch to the ON position. Continue to hold transmitter 
button for 8 - 10 seconds. You will hear a single or a series of beeps, 
followed by a pause then a single beep. Release transmitter’s button. 
Your personal code is now programmed. 

NOTE

: The button you chose 

will be the button used to operate your system.

•  An infinite number of the transmitters can be used, provided that 

the dip switches are set to match one another.

Remove back cover of the opener remote.

Flip opener remote over. Use small screwdriver to move switches 
to random positions. If you have more than one transmitter, now 
is a good time to set them all with the same code.

1

1 2 3 4 5 6 7 8 9

2

All Mighty Mule transmitters are set to a standard code at the factory. However, for your safety and security, we 

strongly recommend

 that you replace the factory setting with your own personal code. Follow the directions below:

Summary of Contents for Mighty Mule MM271

Page 1: ...box from transformer wire not included Power Cable Closed Position Stop Plate PVC conduit not included to protect wire from lawn mowers and weed eaters Gate Bracket Warning Sign Single Gate Operator 1...

Page 2: ...if you fail to do so Nortek Security and Control LLC shall in no event be liable for direct indirect incidental special or consequential damages or loss of profits whether based in contract tort or a...

Page 3: ...lad to give you the name and phone number of a Linear dealer near you BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR Read these instructions carefully to become familiar with all parts and i...

Page 4: ...t from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gate to activate the gate operator 5 Do not activate your gate o...

Page 5: ...at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy FOR THE INSTALLER AND END USER FOR THE INSTALLER AND END USER Mighty Mule gate operators...

Page 6: ...ded not included 7 foot minimum Important Safety Information Important Safety Information Warning signs alert people of automatic gate operation and are required when installing Mighty Mule Automatic...

Page 7: ...TE ACTIVITY CHART Single Gate Winter Ratings Zone 1 Zone 2 Zone 3 12 v single gate 10 watts solar charger 8 16 26 12 v single gate 20 watts solar charger 14 28 38 12 v single gate 30 watts solar charg...

Page 8: ...rator near the center line of the gate to keep the gate from twisting and flexing and to avoid back splash from rain Copper clad ground rod not included Ground Ground 2 Inches or Less above ground Cop...

Page 9: ...me types of installations require u bolts Additional washers or a metal plate may be needed for wooden post Weatherproof cover for outdoor outlet and transformer If the post is larger than 6 bolts lon...

Page 10: ...post and gate cross support Attach post bracket assembly to gate post NOTE Must be through bolted GATE OPERATOR INSTALLATION 1 2 3 5 6 12 T L L V P 2 1 1 13 2 14 15 4 H 1 5 1 2 2 1 Attach and secure o...

Page 11: ...CHGR OFF 120 AUTO CLOSE TIM E MIN MAX STA LL FORCE 6 Locate power outlet and identify wire path to control box NOTE If OUTLET is OUTSIDE use weatherproof cover Inspect the wire to insure the preventi...

Page 12: ...HGR terminal Solar Panels connect in PARALLEL Position solar panel facing sun and in a non shaded open area that allows 8 hours of direct sunlight for a full charge SOLAR PANEL INSTALLATION For multip...

Page 13: ...an radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferen...

Page 14: ...tructing from its own weight or the wind conditions in your area You may need to increase the stall force in cold weather due to increased resistance from gate hinges However the adjustment must remai...

Page 15: ...ntact edge sensor Activation of this input while gate is moving will cause it to reverse direction for 2 seconds Activation of this input while idle will prevent gate from running 8 COM Common Negativ...

Page 16: ...Gate h h Gate for Level and Plumb h h Stall Force Adjustment h h Disconnect Obstruction Detection Devices h h Battery connections h h Check fuse 1 beep every 20 seconds off Low Battery Condition h h T...

Page 17: ...Time Fax 850 575 8950 Web site www mightymule com Telephone 800 543 1236 For 24 hour 7 days a week trouble shooting and sup port online go to our TECH WIZARD site at www mightymule com Repair Service...

Page 18: ...s for maximum stability and security Comes with a keyed manual release Accessories Replacement Transformer RB571 Standard 18 volt 2260 mA AC transformer for maintaining the battery with the Mighty Mul...

Page 19: ...ffic must use the pedestrian gate 5 Warning signs have been installed on each side of the gate in highly visible locations These signs must remain at all times 6 There are no controls installed on the...

Reviews: