NanoQuest Simple Installation Guide

 

 

DOC0053_Issue2.2 

Connecting the NanoQuest Using Normally Closed Contacts 

 

 

Connecting the NanoQuest Using Normally Open Contacts 

Power Up and Confidence Check 

Apply power to the unit and check 

that the LED’s glows red.  

Present a Master Card once to the face of the unit and check that the buzzer gives two short beeps 
and the LED’s blink green and then continue to flash red. Wait 30 seconds. The buzzer should give 
two short beeps and the LED’s return to a steady Red. 

Press the Free Exit Button, if fitted. The NanoQuest will give a short beep, the lock will release for 3 
seconds and the LED’s change to green during this period. This indicates that the unit is functioning 
correctly.

Summary of Contents for NanoQuest

Page 1: ...xterior use but it must not be used for an exterior door without another means of securing the door For example a dead lock secures the door at night with NanoQuest controlling access by staff during the day 2 Use the supplied template to mark out the positions of the holes for screw fixings and cable access and drill appropriate sized holes 3 Remove the cover from the NanoQuest by inserting the t...

Page 2: ...sent a Master Card once to the face of the unit and check that the buzzer gives two short beeps and the LED s blink green and then continue to flash red Wait 30 seconds The buzzer should give two short beeps and the LED s return to a steady Red Press the Free Exit Button if fitted The NanoQuest will give a short beep the lock will release for 3 seconds and the LED s change to green during this per...

Page 3: ...t steps to the next function see the table below Once you have adjusted the setting by presenting the appropriate user cards you can exit programming mode by presenting the Master Card again Note When in programming mode the LED provides an indication of the mode option that has been selected by blinking red the number of times that correspond with the selection made For example when in mode 5 con...

Page 4: ...y in arming see below Orange Black Relay common Green Black RS232 serial data Green White Normally open contact Blue Black Wiegand mode select connect to VE for Wiegand Blue White Normally closed contact Specifications Number of users 500 Door Open time 0 5 to 10 seconds plus Latch mode e g for secure control of equipment Aux out Latch or Pulse after 3 shows of selected cards Aux in Open for readi...

Reviews: