Nortech Detection Pty Ltd PD130 Short Form User Manual Download Page 8

PD130 Enhanced - User Instructions

Page 8 of 12

Figure 6.1 PD130 Housing dimension

7.

Wiring Connections

11-pin connector wiring

pin

colour

designation

1

Red

Live

230V AC 50/60 Hz

2

Black

Neutral

OR 12 - 24V AC/DC

3

Grey

Pulse Relay

Normally Open contact

4

Violet

Pulse Relay

Common contact

5

Yellow

Presence Relay

Normally Open contact

6

Brown

Presence Relay

Common contact

7

Blue

Loop

Twist this

8

Blue

Loop

pair

9

Green

Earth

10

Pink

Presence Relay

Normally Closed contact

11

White

Pulse Relay

Normally Closed contact

8.

Part Numbers

Part Number

Model Number

Description

301FT0101_01

PD132 - Enhanced

230 V ac operation

301FT0122_01

PD134 - Enhanced

12 - 24V ac/dc operation

895FT 0001

DU100 - English

Hand Held Diagnostic Unit

301FT0041

Wiring Harness

Option - 1 metre plug and harness

CTR119090

DIN Rail Screw terminal base

Summary of Contents for PD130

Page 1: ...under the road surface The detector has been designed for ease of installation and convenience The various modes are selected by changing the positions of the switch on the front of the unit The swit...

Page 2: ...3 Sensing Loop Geometry 9 10 Loop Installation 10 11 Fault Finding 12 12 Warranty 12 13 Sales and Technical support 12 2 User Warnings WARNING This unit when installed must be correctly earthed WARNI...

Page 3: ...ations will be accommodated in the tuning range of the detector Once tuned any slow environmental change in loop inductance is fed to a compensating circuit within the detector that keeps the detector...

Page 4: ...as follows When ASB is disabled the undetect level is dependent on the sensitivity setting of the detector Hence as the detector is made less sensitive the undetect level will reduce accordingly When...

Page 5: ...sensitivity selections and these are set as follows SW4 SW3 Off Off High On Off Medium High Off On Medium Low On On Low 5 1 3 Automatic Sensitivity Boost Automatic sensitivity boost is a mode that alt...

Page 6: ...This operation is also performed whenever the reset button is depressed The ON red LED will glow permanently to indicate that the unit is functional The red LED also serves as an optical interface to...

Page 7: ...e tubes and Zener diode clamping on loop input Power requirements 12 V 10 to 24 V 10 PD134 230 VAC 10 48 to 62Hz PD132 1 5 VA Maximum 230 V Relay Contact Rating Relays rated 5 A 230 VAC Factory Option...

Page 8: ...lay Normally Open contact 6 Brown Presence Relay Common contact 7 Blue Loop Twist this 8 Blue Loop pair 9 Green Earth 10 Pink Presence Relay Normally Closed contact 11 White Pulse Relay Normally Close...

Page 9: ...e screen must be earthed at the detector end only 9 1 2 Reinforcing The existence of reinforced steel below the road surface has the effect of reducing the inductance and therefore the sensitivity of...

Page 10: ...can be caused to the loop at right angle corners NOMINAL SLOT WIDTH 45mm NOMINAL SLOT DEPTH 30mm TO 50mm A slot must also be cut from the loop circumference at one corner of the loop to the roadway ed...

Page 11: ...PD130 Enhanced User Instructions Page 11 of 12 Figure 10 2 Adjacent loops connected to different detector modules...

Page 12: ...onnected and adequately twisted c Isolate sources of nearby electrical equipment and high voltage cables 12 Warranty i A conditional 24 month Warranty is offered on all items covering faulty workmansh...

Reviews: