Short form User Manual

PD130 Enhanced Vehicle Detector

The PD130 is a single channel microprocessor based detector designed specifically for parking and vehicle access

control application. The PD130 has been designed using the most up-to-date technology in order to meet the
requirements of a vast number of parking applications in terms of operating conditions and options available to the user.

The primary function of the detector is to detect vehicle presence by means of an inductance change caused by the
vehicle passing over a wire loop buried under the road surface.

The detector has been designed for ease of installation and convenience. The various modes are selected by changing

the positions of the switch on the front of the unit.

The switches allow for different loop frequency settings, sensitivity settings and mode settings.

The PD130 provides visual output (LED) on the front of the enclosure and relay changeover contacts are taken on the
11-pin connector at the rear of the enclosure. The LED indicates the power has been applied to the unit, that a vehicle is

present over the loop and if there is a fault on the loop. The Presence relay is fail-safe and will close on a vehicle detect
or in the event of power failure.

In accordance with the manufacturer’s policy of updating and improving product designs, product specification is
subject to change without notice. While every care has been taken with the preparation of this document, no warranty

is offered to the completeness or accuracy of this information.

Summary of Contents for PD130

Page 1: ...under the road surface The detector has been designed for ease of installation and convenience The various modes are selected by changing the positions of the switch on the front of the unit The swit...

Page 2: ...3 Sensing Loop Geometry 9 10 Loop Installation 10 11 Fault Finding 12 12 Warranty 12 13 Sales and Technical support 12 2 User Warnings WARNING This unit when installed must be correctly earthed WARNI...

Page 3: ...ations will be accommodated in the tuning range of the detector Once tuned any slow environmental change in loop inductance is fed to a compensating circuit within the detector that keeps the detector...

Page 4: ...as follows When ASB is disabled the undetect level is dependent on the sensitivity setting of the detector Hence as the detector is made less sensitive the undetect level will reduce accordingly When...

Page 5: ...sensitivity selections and these are set as follows SW4 SW3 Off Off High On Off Medium High Off On Medium Low On On Low 5 1 3 Automatic Sensitivity Boost Automatic sensitivity boost is a mode that alt...

Page 6: ...This operation is also performed whenever the reset button is depressed The ON red LED will glow permanently to indicate that the unit is functional The red LED also serves as an optical interface to...

Page 7: ...e tubes and Zener diode clamping on loop input Power requirements 12 V 10 to 24 V 10 PD134 230 VAC 10 48 to 62Hz PD132 1 5 VA Maximum 230 V Relay Contact Rating Relays rated 5 A 230 VAC Factory Option...

Page 8: ...lay Normally Open contact 6 Brown Presence Relay Common contact 7 Blue Loop Twist this 8 Blue Loop pair 9 Green Earth 10 Pink Presence Relay Normally Closed contact 11 White Pulse Relay Normally Close...

Page 9: ...e screen must be earthed at the detector end only 9 1 2 Reinforcing The existence of reinforced steel below the road surface has the effect of reducing the inductance and therefore the sensitivity of...

Page 10: ...can be caused to the loop at right angle corners NOMINAL SLOT WIDTH 45mm NOMINAL SLOT DEPTH 30mm TO 50mm A slot must also be cut from the loop circumference at one corner of the loop to the roadway ed...

Page 11: ...PD130 Enhanced User Instructions Page 11 of 12 Figure 10 2 Adjacent loops connected to different detector modules...

Page 12: ...onnected and adequately twisted c Isolate sources of nearby electrical equipment and high voltage cables 12 Warranty i A conditional 24 month Warranty is offered on all items covering faulty workmansh...