Key benefits of the innovative V-Profile humidifier media box: 
 

 

Low Pressure Drop 

 

Hygroscopic Coating 

 

UL 900 Class 1 Rating 

 

High Velocity Performance  

 

Suitable for all Water Quality 

 

No Droplets, Free of Aerosols 

 

 
MHTC - Total Control System  
 

The MH control unit controls the humidity and governs the water management to maximize efficiency. The integrated processor 
with real-time clock controls the air humidity, pre-cleaning sequences, unit purging and water quality control, all fully automatically. 
The controller is designed for connection to building management systems (BMS). This means that parameters such as 
humidifying requirement, water consumption, maintenance requirement or operating hours can be transmitted further via modbus, 
LON Talk or BACnet with 

LINKS2.

 

 

The electronic control cabinet includes electrical fusing and main power switch. 
One, two or three stage control through magnetic staging valves is available. Microprocessor PI-controlled analog humidity signals 
for flexibility. Controlled flushing of the water tank in function of the filling cycles or time controlled drainage through the integrated 
real time clock. Programmable wash cycle for cleaning the humidification media. Automatic flushing of the water lines at the end of 
a season shutdown or without a call for humidity. An automatic forced drain after shutdown periods longer than 72 hours, an 
interruption in humidifying requirement of over 72 hours or in the case of a power failure.  

 
 

 

 

TC Total Controller Management System 

 
 

Key Benefits: 

 

Smart Water Management 

 

Advanced Hygiene Control 

 

Capable of Monitoring & Control via Internet or BMS 

 

Full Functional Operating Panel 

 

Adjustable Flush Cycles  

 

Pre-Cleaning Sequence 

 

Programmable Maintenance  

 

Conductivity Monitoring 

 

UV Sensing  

 
 

Summary of Contents for MHTC

Page 1: ...is R O and fully de ionized D I water Adiabatic evaporation cooling of over 21 5 F 12 C can be achieved Ultra violet water treatment available The electronic control is an integral part of the humidifier It enables operation free of malfunctions and optimises control accuracy and water consumption The short stainless steel water tank depth will reduce on the overall footprint saving valuable air h...

Page 2: ...onic control cabinet includes electrical fusing and main power switch One two or three stage control through magnetic staging valves is available Microprocessor PI controlled analog humidity signals for flexibility Controlled flushing of the water tank in function of the filling cycles or time controlled drainage through the integrated real time clock Programmable wash cycle for cleaning the humid...

Page 3: ...ucer Sensor Controls P N 1509858 2 10V Dig Wall Humidity Sensor P N 1509857 2 10V Duct Humidity Sensor Nortec LINKS2 and Nortec Online please consult factory MHTC REflow Technical data Humidifying output see performance data Power consumption w UV 0 60 kW Power consumption w o UV 0 50 kW Primary voltage 120 1 60 V Ph Hz Control voltage 24V ac Modulation Water mains pressure 30 145 psi Water connec...

Page 4: ...4 200 mA F1 6 3 A F3 630 mA F2 1 0 A Main Switch Primary Terminal Block Internal External Drain Valve Inlet Valve Stage 1 Valve Stage 2 Valve Stage 3 Valve X6 N Stage 3 Stage 2 Stage 1 24 Vac Security Loop GND Channel 1 5 Vdc GND M Optional UV Lamp Recirculation Pump ON Active Service Fault 4 2 3 5 1 L1 N 8 9 10 11 13 12 15 14 17 16 3 4 5 7 6 1 2 10 11 9 8 14 16 17 1 2 120 24 Vac Hydraulic Unit In...

Page 5: ......

Page 6: ......

Page 7: ...lation duct or air handling unit very quickly The media boxes can be mounted in the simplest of manners and only three connections are needed the supply inlet water valve drain water valve and all electrical control connections The REflow model incorporates a 120V single phase connection Typical MH installation Use as reference only MHTC REflow shown ...