background image

WARRANTY:

 Under normal use the Company warrants 

to the purchaser that defects in material or workmanship 
will be repaired or replaced without charge for a period 
of 18 months from date of shipment, or 12 months from 

the start date of operation, whichever expires fi rst. Any 
claim for warranty must be reported to the sales offi ce 

where the product was purchased for authorized repair or 
replacement within the terms of this warranty. 

Subject to State or Provincial law to the contrary, the 

Company will not be responsible for any expense for 
installation, removal from service, transportation, or 
damages of any type whatsoever, including damages 
arising from lack of use, business interruptions, or 
incidental or consequential damages.

The Company cannot anticipate or control the conditions 
of product usage and therefore accepts no responsibility 
for the safe application and suitability of its products when 
used alone or in combination with other products. Tests 
for the safe application and suitability of the products are 
the sole responsibility of the user.

This warranty will be void if, in the judgment of the 
Company, the damage, failure or defect is the result of:

• 

Vibration, radiation, erosion, corrosion, process 
contamination, abnormal process conditions, 
temperature and pressures, unusual surges or pulsation, 
fouling, ordinary wear and tear, lack of maintenance, 
incorrectly applied utilities such as voltage, air, gas, water, 
and others or any combination of the aforementioned 

causes not specifi cally allowed for in the design 

conditions or,  

• 

Any act or omission by the Purchaser, its agents, 

servants or independent contractors which for greater 
certainty, but not so as to limit the generality of the 
foregoing, includes physical, chemical or mechanical 
abuse, accident, improper installation of the product, 
improper storage and handling of the product, improper 
application or the misalignment of parts.

No warranty applies to paint fi nishes except for manufacturing 

defects apparent within 30 days from the date of installation.

The Company neither assumes nor authorizes any person to 
assume for it any other obligation or liability in connection 

with the product(s).

The Purchaser agrees that all warranty work required after 

the initial commissioning of the product will be provided 

only if the Company has been paid by the Purchaser in full 

accordance with the terms and conditions of the contract.

The Purchaser agrees that the Company makes no warranty 
or guarantee, express, implied or statutory, (including any 
warranty of merchantability or warranty of fi tness for a 
particular purpose) written or oral, of the Article or incidental 

labour, except as is expressed or contained in the agreement 
herein.

LIABILITY: 

Technical data contained in the catalog or 

on the website is subject to change without notice. The 
Company reserves the right to make dimensional and other 

design changes as required. The Purchaser acknowledges 

the Company shall not be obligated to modify those articles 
manufactured before the formulation of the changes in 
design or improvements of the products by the Company.

The Company shall not be liable to compensate or indemnify 

the Purchaser, end user or any other party against any actions, 

claims, liabilities, injury, loss, loss of use, loss of business, 
damages, indirect or consequential damages, demands, 

penalties, fi nes, expenses (including legal expenses), costs, 

obligations and causes of action of any kind arising wholly or 
partly from negligence or omission of the user or the misuse, 
incorrect application, unsafe application, incorrect storage 
and handling, incorrect installation, lack of maintenance, 
improper maintenance or improper operation of products 
furnished by the Company.

Oakville

1-800-410-3131
1-905-829-4422
F 905-829-4430

Orillia

1-877-325-3473
1-705-325-3473
F 705-325-2106

Edmonton

1-780-466-3178
F 780-468-5904

5918 Roper Road
Alberta, Canada T6B 3E1

Houston

1-800-654-2583
1-713-433-2600
F 713-433-4541

Denver

1-855-244-3128
1-303-979-7339
F 303-979-7350

For further assistance, please call 24hr hotline: 1.800.661.8529  (U.S.A. and Canada)
Please have model and serial numbers available before calling.

PLEASE ADHERE TO INSTRUCTIONS IN THIS MANUAL

Failure to do so may be dangerous and may void certain 
provisions of your warranty.

Summary of Contents for XGB Series

Page 1: ...ided can result in personal injury or damage to the equipment This symbol indicates a potentially hazardous situation which if not avoided may be a shock hazard This symbol indicates an imminently hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION WARNING WARNING WARNING Improper installation adjustment alteration excessive vibration service or mainten...

Page 2: ...3 A 8 Accesories 3 B Pre Installation 5 C Installation and Mounting 5 C 1 Dimensions 5 C 2 Mounting 5 C 3 Mounting with Standard Kits 6 C 4 Outlet Louvres 8 C 5 Wiring 8 D Options 9 D 1 Temperature Control 9 D 2 AUTO OFF FAN ONLY Optional 9 E Normal Sequence of Operation 10 F Maintenance 10 F 1 Motor 10 F 2 Fan Blade 10 F 3 Heater Cabinet 10 F 4 Overheat Protection 10 F 5 Replacement Parts List 11...

Page 3: ... 2 Groups E F G NOTE Class II and some atmospheric groups are not available in every kW rating ࢦ Zone marking available ࢦ Ratings from 3 75 to 35 kW ࢦ 208 to 600V 1 or 3 phase ࢦ Low watt density extra heavy wall tubular steel finned heating elements with nickel plated finish ࢦ Glycol free design allows the heater to be tilted 30º downward ࢦ Rotatable outlet louvers provide 35º of additional airflo...

Page 4: ...ction Figure 1 Small Cabinet XGB Unit Heater Components Standard Features Large Cabinet Unit 1 1 2 hp explosion proof motor 2 Inlet wire guard 3 Extra heavy wall tubular steel finned heating elements with nickel plated finish 4 Patented x Max explosion proof terminal housing 5 120V control circuit includes Derated magnetic contactor Dual automatic reset high limits Transformer Fan delay relay Cont...

Page 5: ...del could weigh up to 185 lbs 84 kg Provide sufficient stiffness to prevent excessive vibration and withstand harsh situations such as transportable installations See C 1 Dimensions page 5 for heater dimensions and weights 2 The heater must be positioned with a minimum 15 cm 6 side clearance from all surrounding surfaces and must be mounted at least 61 cm 24 from the floor for small cabinet units ...

Page 6: ... bolt SWIVEL MOUNTING BRACKET MOUNTING SURFACE 11 16 dia mounting holes 5 8 flatwasher lockwasher nut WALL BRACKET LINEA CEILING BRACKET 5 8 Bolt MOUNTING BAR 3 8 flatwasher lockwasher nut 1 2 flatwasher lockwasher nut 3 8 Bolt 1 2 Bolt SWIVEL MOUNTING BRACKET 5 8 Bolt Figure 4 Ceiling Mounting 2 Wall Mounting 2 1 Install the ceiling bracket to the wall bracket with the desired orientation Ensure ...

Page 7: ...irable Telescoping square tubing on a support base allows the unit to be positioned at the desired height above the floor anywhere between 1 8 m 6 to 3 m 10 4 2 Position the base of the stand on the floor in the desired orientation Ensure that LINE A Figure 7 page 7 a line drawn perpendicular to the bolt holes in the mounting bar is pointed in the desired direction of air flow 4 3 Next the stand i...

Page 8: ...ng with the trolley See Figure 9 and Figure 10 page 9 for control circuit and Figure 11 page 9 for suggested wiring Exercise care to avoid damage to wires caused by threads on the housing supplied as standard either horizontally or uvers in the horizontal ers to vertical remove uver assembly to the d direction are present ensure tc are secured but ater on before removing ed personnel in strict nd ...

Page 9: ...nd T2 and connect the thermostat to these terminals Refe to Figure 9 Set the temperature to the desired operating condition 5 0 AUTO OFF FAN ONLY SWITCH OPTIONAL If ordered a factory installed auto off fan only switch may b included on the heater The fan only feature allows the heater t cycle in a heat mode dictated by the controlling thermostat eve though the fan is operating continuously 6 0 NOR...

Page 10: ... life of the heater and its components Always disconnect the electrical supply before performing any maintenance 2 Periodically inspect the heater installation to ensure that all connections fittings plugs screws covers etc are tight and free of corrosion 3 Check the inside of the cabinet and around the element fins for dust build up and debris especially after seasonal shutdowns Clean with an air...

Page 11: ...1 T3A T Code C12023 10 T3B T Code C12023 10 Motor All units B14302 01 Contactor All units 13463 Fan Blade 10 7 5 kW C11028 05 5 3 75 kW C11028 06 Table 5 Large Cabinet Units Part Unit Description Part No Transformers 208V EXA50 23 240V EXA50 25 480V EXA50 36 600V EXA50 39 High Limits T2C T Code C12023 11 T2D T Code C12023 11 T3A T Code C12023 10 T3B T Code C12023 12 Motor 208 to 480V 3Ø 1699 240V ...

Page 12: ...pany neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product s The Purchaser agrees that all warranty work required after the initial commissioning of the product will be provided only if the Company has been paid by the Purchaser in full accordance with the terms and conditions of the contract The Purchaser agrees that the Compan...

Page 13: ...Part No 11110 Rev 1 04 janv 2021 Imprimé au Canada XGB Series Unités de chauffage antidéflagrantes Instructions d installation d utilisation et d entretien La conception sans glycol ...

Page 14: ...ion 15 A 4 Caractéristiques standard 15 A 5 Options 15 A 6 Thermostats 15 A 7 Moteurs 15 A 8 Accessoires 16 B Avant l installation 17 C Installation et montage 17 C 1 Dimensions 17 C 2 Montage 17 C 3 Montage avec les trousses de série 18 F 6 Auvents de sortie 20 F 7 Cablâge 20 Table des matières ...

Page 15: ...droits dangereux Unités à petit cabinet homologuées classe I div 1 et 2 groupe D classe II div 1 et 2 groupes E F et G Unités à grand cabinet homologuées classe I div 1 et 2 groupes C et D classe II div 1 et 2 groupes E F et G Remarque La classe II et certains groupes atmosphériques peuvent ne pas être offerts à toutes les cotes kW ࢦ Marquage par zone ࢦ Modèles offerts entre 3 75 et 35 kW ࢦ 208 à ...

Page 16: ...ées de réinitialisation automatique Transformateur 6 Heavy duty 16 ga stainless steel casing 7 Boîtier robuste en acier inoxydable de ca 16 8 Auvent de sortie 9 Support de fixation pivotant 10 Joints de passage en série 11 Boîtier du bornier d alimentation 12 Borniers de l alimentation et du thermostat externe Figure 1 Composants de l unité de chauffage XGB à petit cabinet Caractéristiques de séri...

Page 17: ...èle peut atteindre 84 kg 185 lb Assurer assez de robustesse de manière à prévenir la vibration excessive et résister aux situations les plus difficiles comme les installations transportables Reportez vous à la section C 1 Dimensions page 17 pour les dimensions et poids 2 L unité de chauffage doit être positionnée à 15 cm 6 po d espace au minimum de toutes les surfaces environnantes et montée au mo...

Page 18: ... Support plafonnier Barre de montage 3 8 Rondelle plate boulon d arrêt écrou 1 2 Rondelle plate boulon d arrêt écrou Surface de montage 11 16 po de diamètre Trous de montage Support pour montage pivotant 3 8 boulon 1 2 boulon LIGNE A Figure 4 Montage au plafond 2 Fixation au mur 2 1 Fixer le support plafonnier au support mural avec l orientation préférée Assurer que la LIGNE A Figure 5 page 18 la ...

Page 19: ...tuation l unité peut être fixée à un pied Un tuyau télescopique carré sur un pied de fixation permet de positionner l unité à la distance souhaitée du sol entre 1 8 et 3 m 6 et 10 pi 4 2 Positionner la base du pied sur le plancher à l orientation souhaitée Assurer que la LIGNE A Figure 7 page 19 la ligne perpendiculaire entre les trous de boulonnage de la barre de fixation sont pointées dans le se...

Page 20: ...ableau 2 Petit cabinet Catalog Number kW Tension Intensité maximale Taille de fusible recommandé amp 1 Ø 3 Ø 1 Ø 3 Ø XGB038T3B 3 75 208 19 11 25 15 240 17 10 25 15 480 6 10 600 5 10 XGB050T3B 5 208 25 15 35 20 240 22 13 30 20 480 7 10 600 6 10 XGB075T3A 7 5 208 37 22 50 30 240 32 19 40 25 480 10 15 600 8 10 XGB100T2C 10 208 29 40 240 43 25 60 35 480 13 20 600 11 15 Tableau 3 Grand cabinet Catalog ...

Page 21: ...erature to the desired operating condition 5 0 AUTO OFF FAN ONLY SWITCH OPTIONAL If ordered a factory installed auto off fan only switch may b included on the heater The fan only feature allows the heater t cycle in a heat mode dictated by the controlling thermostat eve though the fan is operating continuously 6 0 NORMAL SEQUENCE OF OPERATION 6 1 The heater must be properly mounted and wired in ac...

Page 22: ...fage et de ses composants Déconnecter l alimentation électrique avant d effectuer l entretien 2 Inspecter régulièrement l installation de l unité de chauffage afin d assurer que les connexions les raccords les fiches les vis les couvercles et autres sont bien ajustés et exempts de corrosion 3 Vérifier l intérieur du cabinet et les alentours des éléments de manière à enlever la poussière et les déb...

Page 23: ... T Code C12023 12 Moteur 208 to 480V 3Ø 1699 240V 1Ø 1979 600V 2433 Contacteur Toutes les unités 42CF35AF Pale de ventilateur Toutes les unités 10873 Fusible de commande Toutes les unités MDL 0 6 Tableau 5 Grand cabinet Part Description de l unité Part No Transformateur 208V EXA50 23 240V EXA50 25 480V EXA50 36 600V EXA50 39 Limites élevées T2C T Code C12023 11 T2D T Code C12023 11 T3A T Code C120...

Page 24: ...imiter la généralité de ce qui précède une mauvaise utilisation physique chimique ou mécanique un accident une mauvaise installation du produit de mauvaises conditions de stockage ou de manipulation du produit une application inappropriée ou en défaut d alignment des pièces Aucune garantie ne s applique à la finition de peinture excepté dans le cas de défauts de fabrication apparents dans les 30 j...

Reviews: