25
5.3 Troubleshooting
Searchlight don t move on horizontal or vertical:
In case of Alarm Horizontal blocked or Vertical blocked, check that cables is not restricting
movement.
In case of too much ice around the forks it can be blocked.
Sensor fault, check I/O-signals on the panel searchlight.
The light does not turn on
Check on the lamp that get the ignition spark
Check that the power supply is on
Check fuses on the power-supply
Check On/Off switch for remote signal on the power-supply.
Correct position is Off
Focus does not work:
Check that limitswitches is work
Yellow indicator for switches cannot be On at the same time
Com error in main menu:
Check power to the ethernet-switch
Check power to the searchlight
Check LAN-cables
Joystick double command:
Two persons is trying to control the same searchlight
Battery error:
Change battery in PLC in searchlight or panel.
5.4 Battery (2008190) error and replacement
1. Change battery in PLC in the panel or searchlight
2. Battery replacement in the PLC:
Pull the white connector
from the board.
Dispose battery
professionally
Connect new battery
with the white-coded
connectors on the board
Summary of Contents for R60 Series
Page 1: ...1 INSTALLATION USER MANUAL SEARCHLIGHTS HALOGEN R60 ...
Page 10: ...10 3 0 Electrical Installation 3 1 R60 SH 310 SH 480 System Layout ...
Page 19: ...19 4 3 Searchlight help and information Help menu In most of the menues Help is available ...
Page 20: ...20 ...
Page 27: ...27 7 1 R60 Searchlight PLC B2 Motorhouse ...
Page 28: ...28 7 2 R60 Searchlight PLC Output B2 Motorhouse ...
Page 30: ...30 7 4 R60 Motorhouse B2 ...
Page 31: ...31 7 5 R60 Drum Gear B2 ...
Page 32: ...32 7 6 R60 Slave panel B6 ...