38
© 2020 Norsat International Incorporated (“Norsat”) All Rights Reserved
DOC-000848 Rev A 10/2019
Invalid Command CheckSum The client is sending commands with invalid CheckSum values to the server
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
Targeting Error
Verify that the data entered in the Satellite Almanac for the target satellite is correct
Verify that the antenna feed has a direct line-of-sight to the target satellite
Verify that the antenna’s GPS coordinates are correct
Verify that the antenna is capable of achieving the required target orientation
Compass Re-Calibration
Required, or Terminal Is Not
Level
Verify that the antenna is properly leveled
Calibrate compass by selecting Administration > Calibrate Compass
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
Hardware Error
Restore the terminal to Factory Default Settings
Once the issue has been fixed, the system must be power cycled to clear the alarm
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
Inclinometer not Connected Check the MC and Power cable connections between the Antenna and the ACU
Restore the terminal to Factory Default Settings
Once the issue has been fixed, the system must be power cycled to clear the alarm
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
GPS not connected
Check the MC and Power cable connections between the Antenna and the ACU
Restore the terminal to Factory Default Settings
Once the issue has been fixed, the system must be power cycled to clear the alarm
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
Compass not connected
Check the MC and Power cable connections between the Antenna and the ACU
Restore the terminal to Factory Default Settings
Once the issue has been fixed, the system must be power cycled to clear the alarm
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
DVB Receiver not connected Check the cable connections inside the ACU for the DVB receiver
Once the issue has been fixed, the system must be power cycled to clear the alarm
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal
Beacon Receiver Not
Connected
Check the cable connections inside the ACU for the Beacon receiver
Once the issue has been fixed, the system must be power cycled to clear the alarm
Please contact the terminal manufacturer if this issue persists after power cycling
the terminal