A: For wooden windows:
Drive 1/ 2" (12.7 mm) locking screws
through the frame lock and into the sill
(Fig.15A).
NOTE: To prevent window sill from splitting,
drill 1/8" (3mm) pilot holes before driving
screws. Drive 1/2" (12.7mm) locking screws
through frame holes into window sash
(Fig.15B).
B: For Vinyl-Clad windows:
Drive 1/2" (12.7 mm) locking screws
through the frame lock and into the window
sashl (Fig.15B).
NOTE: Before driving the screws, use a
drill to drill 5 holes through the holes in the
frame lock and frame extensions into the
windows sash as shown (Fig. 15B).
Figure 14
Wooden windows
Vinyl-Clad windows
Figure 15A
Figure 15B
16
INSTALL SUPPORT BRACKET
Figure 13
Window
Frame
1. Place the frame lock (b) between the
frame extensions and the window sill
(See Figure 14). Drive 3/4” (19mm)or 1/2”
(12.7mm) locking screws (a) through the
frame lock and into the sill.
NOTE
: To prevent window sill from
splitting, drill 1 / 8” (3mm) pilot holes
before driving screws.
2.
NOTE
: Check that the air
conditioner is tilted back about
3° to 4° down towards the
outside (Figure 12). After proper
installation, if condensation does
hole during normal use, correct
the angle of the slope.
2. Extend the side panels out against
the window frame (Figure 13).