2-10
Tests and adjustments
.
Table 2-1 MB Configuration settings
S1 and S3 will decide the model (NM 7050 A, B, C or D) and show up in the
Link Status
win-
dow in the RMM program and the
Initial Window
in the LCD menu. A disagreement between
the settings and the actual number of modules will cause a
M
AINTENANCE
W
ARNING
on the
Front Panel
and an
E
RROR
in the
Maintenance
window.
With S2 =
I
N
the A
CCESS
G
RANT
switch on the
Remote Control
will have no effect. You may
still acquire
ACCESS
LEVEL
2
and
3
on the
RMM remote port
if the settings of S6 and S7 per-
mits.
S4 decides weather lost communication with the
Remote Control
will cause shutdown (no TX
to air) or not.
S5 instructs the transmitter control software weather a failed standby transmitter will be shut
down or continue to transmit.
S6 and S7 decides the highest
ACCESS
LEVEL
permitted on the
RMM remote port
. All access
levels are available on the RMM local port regardless of S6 and S7.
2.2.2
Setting inner, outer or middle marker
To configure the beacon for outer, middle or inner marker set the straps (S1-S4) on the trans-
mitter board(s) according to Table 2-2.
Table 2-2 Marker function configuration
Strap no State
Function
S1
Strap
IN
2 power supplies
(NM 7050 B/D)
Strap
OUT
1 power supply
(NM 7050 A/C)
S2
Strap
IN
Access Grant disabled
Strap
OUT
Access Grant enabled
S3
Strap
IN
2 monitor units
(NM 7050 C/D)
Strap
OUT
1 monitor unit
(NM 7050 A/B)
S4
Strap
IN
Lost contact with remote control will NOT cause shutdown
Strap
OUT
Lost contact with remote control will cause shutdown
S5
Strap
IN
Standby transmitter failure will NOTcause shutdown
Strap
OUT
Standby transmitter failure will cause shutdown
S6
Strap
IN
Access level 2 on RMM remote port enabled
Strap
OUT
Access level 2 on RMM remote port disabled
S7
Strap
IN
Access level 3 on RMM remote port enabled
Strap
OUT
Access level 3 on RMM remote port disabled
S8
Should always be left open.
Strap Function with strap in
S1
Beacon is INNER marker
S2
Beacon is MIDDLE marker
S3
Beacon is OUTER marker
S4
Beacon is FAN marker
Summary of Contents for 7050
Page 1: ... 1999 Navia Aviation AS NORMARC 7050 MARKER BEACON Transmitter ...
Page 2: ... 1999 Navia Aviation AS ...
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 19: ......
Page 20: ......