Noritz SS-HB-3 Installation And Maintenance Instructions Manual Download Page 1

1

General Information  
 

 
 
 
 

 
- The information in this instruction manual is subject to modifications without prior notice. 
- Keep the instruction manual for future reference.  

 

Product Identification:

  These instructions apply to the filter housing as specified in 

the package sticker. A label describing working conditions 
is applied to the filter housing. 

 

The sticker and the label must not be removed, tampered with, hidden, covered, 
or changed.  

 

WARNING: The values of the maximum working temperature and the 
maximum working pressure shown in the label affixed to the filter 
housing are intended as maximum working parameters.

 

 

Precautions, Warnings

 

READ ALL INSTRUCTIONS AND PRECAUTIONS BEFORE INSTALLING AND USING 
THIS PRODUCT. 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 

 

Installation

 

Refer to figures: 
A General information. 
B IN - OUT directions presentation in different filter housings models. 
C Installation lay-out (next page): 

1. Water mains | 2. Pressure reducer | 3. Anti-water hammer device 
4. Other utilities | 5. Filter unit of any model 

 

- Before installation, check if the plumbing system has been constructed according to 

the applicable plumbing code.  

- Avoid all kind of stress by using a wall bracket. Should the use of the wall bracket be 

impossible, the installer (qualified and licensed personnel) shall be responsible for the 
most appropriate installation avoiding stress which may affect the housing’s integrity.  

- Connect the inlet to the product’s side with the arrow IN and the oulet to the side 

with the arrow OUT. (Fig. B)  

-

Connect to pipes using tapered fittings, preferably with flexible hoses.  

 

   

Turn-off the water main before installation. 

 

 

- Before installation ensure that any electric plugs in the vicinity of  

the area are disconnected.  

- Before the installation, carefully lubricate the housing o-ring which  

is located at the sump top.  

- Do not use with water that is microbiologically unsafe or of  

unknown quality without adequate disinfection before or after the 
system.  Systems certified for cyst reduction may be used on 
waters that contain filterable cysts.  

INSTALLATION AND  
MAINTENANCE  INSTRUCTIONS 
SS-HB-3

 

 

PLEASE READ THIS INSTRUCTIONS MANUAL THOROUGHLY AND CAREFULLY 
AND UNDERSTAND ITS CONTENTS BEFORE INSTALLING THE FILTER HOUSING.

US

Summary of Contents for SS-HB-3

Page 1: ...ation check if the plumbing system has been constructed according to the applicable plumbing code Avoid all kind of stress by using a wall bracket Should the use of the wall bracket be impossible the...

Page 2: ...p instructions for the insertion of a new cartridge Start Up Keep the housing package with sticker Data Plate to identify the product Ensure that the sealing is tight and secure After the installation...

Page 3: ...sing cartridge be left not in use for more than 1 week replace cartridge s with new one s prior to use Operations for the replacement of a filter cartridge See figures and follow step by step instruct...

Page 4: ...ealant and or connection not sufficiently tightened b Improper connection type REMEDY a Tighten further the housing with the wrench b If the housing still leaks change the housing s o ring with a new...

Page 5: ...ifiez si le syst me de plomberie a t construit conform ment au code de plomberie applicable vitez tout type de stress en utilisant un support mural Si l utilisation du support mural est impossible l i...

Page 6: ...au moins 5 minutes avant utilisation V 1 2 3 V 5 4 3 seulement en cas d installation avec pompe IN IN OUT OUT IN OUT IN IN OUT VV IN OUT IN OUT Modalit s de pr sentation des sens d entr e et de sorti...

Page 7: ...iltre bo tier de la cartouche n est pas utilis pendant plus d une semaine remplacez la les cartouche s par une s neuve s avant de l utiliser Op rations de remplacement d une cartouche filtrante Report...

Page 8: ...s suffisamment serr e b Type de connexion incorrect RECOURS a Serrez davantage le bo tier avec la cl SOLUTION a Serrez davantage le bo tier avec la cl b Si le bo tier fuit toujours remplacez le joint...

Page 9: ...era imposible el uso del soporte de pared el instalador persona calificada y experimentada ser responsable de realizar una instalaci n m s adecuada para evitar tensiones que puedan afectar la integrid...

Page 10: ...ados en la etiqueta pegada al filtro Si la presi n excede las condiciones de trabajo proteja el producto con un reductor de presi n Mant ngalo protegido del calor o el fr o excesivo no exponga a tempe...

Page 11: ...n condiciones de presi n alta pueden ocasionarse roturas PRECAUCI N 5 D new new 1 4 8 9 10 5 6 7 2 3 Operaciones de reemplazo de Cartucho para filtros Consulte las figuras y siga las instrucciones pas...

Page 12: ...ores BSPP paralelos solo se ajustan a los filtros sin la indicaci n NPT en la etiqueta PRECAUCI N Despues de las operaciones de mantenimiento abra el grifo por al menos 5 minutos antes de usar el agua...