![Noritz N-084 Owner'S Manual And Installation Manual Download Page 14](http://html1.mh-extra.com/html/noritz/n-084/n-084_owners-manual-and-installation-manual_1705185014.webp)
26
27
Specifications
Specifications
•
Specifications may be changed without prior notice.
•
The capacity may differ slightly, depending on the water pressure,
water supply, piping conditions, and water temperature.
Performance table
026
031
027
025
029
005
006
022
028
021
008
035
011
035
010
007
009
001
030
003
002
031
012
033
004
031
013
031
014
015
034
020
019
017
034
003
External outfitting
Item
Gas
Consumption
Hot Water
Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG
LP
45
°
F Rise
72
°
F Rise
8.4 Gal./min.
5.3 Gal./min.
0.75-8.4 Gal./min.
99-118,140,167
°
F(14 Options)
108,113,140,167
°
F(Original is 108
°
F)
Maximum Performance
236,000 btuh
236,000 btuh
Minimum Performance
21,000 btuh
21,000 btuh
Specification
N-084
Indoor or Outdoor, Wall Hanging
Power Vented
Direct Ignition
15-150 PSI
0.75 GPM
24.2"(Height) x 18.3"(Width) x 9.4"(Depth)
XXX lbs.
0.3 Gallon
3/4"
3/4"
3/4"
120 VAC (60Hz)
NG: XXXW, LP: XXXW, Freeze Prevention 135W
Zincified Steel Plate/Acryl Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR), Electric Leakage
Prevention Device, Overheat Prevention Device,
Freezing Prevention Device, Fan Rotation Detector
Temperature Control Panel, Anchoring Screws
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
Summary of Contents for N-084
Page 30: ...58...