background image

3

Important Safety Information

A. This Water Heater does not have a pilot. 

It is equipped with an ignition device that 

automatically lights the burner. Do not try 

to light the burner by hand. 

B. BEFORE OPERATING smell all around the 

Water Heater area for evidence of leaking 

gas. Be sure to smell next to the floor 

because some gas is heavier than air and 

will settle on the floor.

  WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

C. Use only your hand to turn the gas valve 

knob. Never use tools. If the knob will not 

turn by hand, don’t try to repair it. Call 

a qualified service technician. Force or 

attempted repair may result in a fire or 

explosion.

D. Do not use this Water Heater if any part 

has been under water. lmmediately call a 

qualified service technician to inspect the 

Water Heater and to replace any damaged 

parts.

When a gas leak is noticed:

1. Stop use immediately.

2. Close the gas valve.

[Indoor Installation]

3. Open windows and doors.
If you detect abnormal combustion or 

abnormal odors, or during an earthquake, 

tornado or fire:

1. Turn off the hot water supply.

2. Turn off the power to the Water Heater.

3. Turn off gas and water supply valves.

4. Call the nearest Noritz agent.
Explosion Hazard;

If the temperature and pressure relief valve 

is dripping or leaking, have a qualified service 

technician replace it. Do not plug or remove 

the valve.

Failure to follow these instructions can result in 

fire or explosion, and personal injury or death.

Check the temperature of the running hot 

water before entering the shower.
Check the temperature before stepping into 

the bathtub.
To prevent burns or scalding, turn off the   

button and wait until the appliance cools 

before performing maintenance.

WARNING

Do not place the exhaust vent terminal in an 

indoor environment by means of adding walls 

and ceiling (Do not enclose using corrugated 

sheets, etc.).

Carbon monoxide poisoning or fire may occur 

as a result.

Leave the proper clearance between the 

Water Heater and nearby objects (trees, 

timber, boxes with flammable materials, etc.).

Do not place combustibles such as laundry, 

newspapers, oils etc. near the heater or the 

exhaust vent terminal. 
Do not install this Water Heater in a 

recreational vehicle or on a boat as this may 

be a Carbon Monoxide Poisoning Hazard. 

Do not install this Water Heater in a mobile 

home when using SV conversion kit (“-SV” 

configuration).
Do not use combustible chemicals such as oil, 

gasoline, benzene etc. in the near the heater 

or the exhaust vent terminal. 
Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity of 

this or any other appliance.
Do not place or use a spray can near the 

Water Heater or the exhaust vent terminal.

*Indicates suggested clearances for maintenance.

[Outdoor Installation]

Left side: 

3 in. (76 mm) 

or more

Right side:

3 in. (76 mm)

or more

Front: 

24 in. (610 mm)*

Top: 

36 in. (910 mm) or more

Left side: 

3 in. (76 mm) 

or more

Right side:

3 in. (76 mm) 

or more

Front: 

24 in. (610 mm)*

3 in.(76 mm)

from exhaust 

vent pipe*

Top:

12 in.(300 mm)

or more

[Indoor Installation]

Summary of Contents for GQ-C2660WXQ-FF US

Page 1: ...he Canadian Standard CAN CSA Z240 MH Mobile Homes Series M86 Noritz America reserves the right to discontinue or change at any time the designs and or specifications of its products without notice NOR...

Page 2: ...dhesives in the same room or area near the Water Heater Keep flammable products 1 Far away from the Water Heater 2 In approved containers 3 Tightly closed 4 Out of children s reach Vapors 1 Cannot be...

Page 3: ...ualified service technician replace it Do not plug or remove the valve Failure to follow these instructions can result in fire or explosion and personal injury or death Check the temperature of the ru...

Page 4: ...y form inside the unit and or cause incomplete combustion damage to the electrical components or electric leakage Do not turn off the Water Heater while someone is bathing Do not cover the Water Heate...

Page 5: ...internal electrical components For single handle fixtures you d turn the handle to the left This appliance is configured for installations up to 2 000 ft above sea level without changes For installati...

Page 6: ...ial Operation 9 Using the Water Heater 10 Setting Hot Water Temperature 10 Customizable Settings 11 Limiting the Maximum Output Temperature 11 Muting the Remote Controller 12 Flow Meter Alarm 12 Stopp...

Page 7: ...er is discharged from the condensate drain pipe approximately 2 gallons h 7 5 L h maximum It is not a water leak Do not plug or block the drain line as it must always be allowed to freely flow Note Th...

Page 8: ...to the Installation Manual 1 POWER Button Indicator For turning the Water Heater ON OFF 2 SETTINGS Button For setting the flow meter alarm and other settings 3 Buttons For setting the hot water tempe...

Page 9: ...you leave the button on and hot water is not used for more than 3 days the stored recirculation operation will be reset To avoid this turn the button off the Remote Controller when hot water will not...

Page 10: ...g 105 F 2 Set the temperature using the buttons 1 The button is ON Operation The POWER indicator is displayed The previously set hot water supply temperature is shown Setting Hot Water Temperature NOT...

Page 11: ...maximum output temperature can be set using the Remote Controller See Customizable Settings 60 C 140 F Display when high temperature is set e g 125 F NOTE Consult local codes for minimum operating te...

Page 12: ...cannot be muted The high temperature warning tone when setting the unit to 125 F 55 C 131 F or higher will not emit a sound when muted 4 Turn on hot water 5 Turn off the hot water when the alarm sound...

Page 13: ...ixtures to their original levels before using the Water Heater again to prevent scalding If there is still a risk that the Water Heater will freeze drain the Water Heater as shown on the next page 1 T...

Page 14: ...D E F and wait until finish draining water b a Freeze damage due to not draining properly will not be covered under warranty Drain water into a bucket to prevent water damage 9 When the water is compl...

Page 15: ...s been out of use for a long time make sure that you fill the condensate trap with water This is to prevent dangerous exhaust gases from entering the building Failure to fill the condensate trap could...

Page 16: ...to clean the Remote Controller discoloration deformation scratches or cracks may occur The Remote Controller is water resistant but not water proof Keep it as dry as possible Water Drain Valve with W...

Page 17: ...s 500 mg L or less Zinc 5 mg L or less Sulfate 250 mg L or less Residual chlorine 4 mg L or less Source EPA National Secondary Drinking Water Regulations 40 CFR Part 143 3 Maximum limit suggested by N...

Page 18: ...ilable from NRCR111DV GQ C3260WXQ FF US is 8 7 GPM 33 L min at a 45 F 25 C temperature rise The maximum flow available from NRCR92DV GQ C2660WXQ FF US is 7 1 GPM 27 L min at a 45 F 25 C temperature ri...

Page 19: ...ilure occurs information relating to the error blinks on the display If this occurs take appropriate measures as the following list The fan can be heard after operation is stopped A motor can be heard...

Page 20: ...rranty period there will be a charge on any service and service will only be performed if the unit is deemed repairable Noritz will stock repair and maintenance parts for this unit for the time period...

Page 21: ...mplete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit WARNING 1 Before the gas conversion is performed verify the prope...

Page 22: ...on NG 218 W LP 202 W Freeze Prevention 114 W NG 185 W LP 175 W Freeze Prevention 114 W Maximum Current 4 Amps Materials Casing Front Cover Hot dipped zinc aluminum magnesium alloy coated steel w Polye...

Page 23: ...y Period is the one used for a commercial capacity Condition C above 8 10 years or 12 500 operational burn hours whichever occurs first 9 5 years or 6 500 operational burn hours whichever occurs first...

Page 24: ...RITZ AMERICA CORP 11160 Grace Avenue Fountain Valley CA 92708 Phone 714 433 2905 Fax 714 241 1514 4 What is Not Covered by this Warranty Please refer to the Installation Manual and Owner s Guide suppl...