Important Safety Information

To prevent damage to property and injury to the user, the icons shown below will be used to warn of varying 

levels of danger.

Every indication is critical to the safe operation of the Water Heater and must be understood and observed.

Potential dangers from accidents during installation and use are divided into the following four categories. 

Closely observe these warnings; they are critical to your safety.

Important Safety Information

Icons warning of risk level

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. 

Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death 

or serious injury.

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor 

or moderate injury.

NOTICE

Indicates a potentially hazardous situation which, if not avoided, may result in 

property damage.

Vapors from flammable liquids will explode 

and catch fire causing death or severe burns.

Do not use or store flammable products such 

as gasoline, solvents or adhesives in the same 

room or area near the Water Heater.

Keep flammable products:

  1. Far away from the Water Heater.

  2. In approved containers.

  3. Tightly closed.

  4. Out of children’s reach.

Vapors:

  1. Cannot be seen.

  2. Vapors are heavier than air.

  3. Go a long way on the floor.

  4.  Can be carried from other rooms to the 

main burner by air currents.

After the Water Heater has been out of use 

for a long time make sure that you fill the 

condensate trap with water.

This is to prevent dangerous exhaust gases 

from entering the building.

Failure to fill the condensate trap could result 

in severe personal injury or death.

(Refer to page 16 for further instructions.)

DANGER

Hot Water Heater temperatures over 125°F 

(52°C) can cause severe burns instantly or 

death from scalding.

Children, disabled and elderly are at the highest 

risk of being scalded. 

Feel water temperature 

before bathing or showering. 

Temperature limiting valves 

are available, consult with 

installer.

Do not use the Water Heater if the intake/

exhaust pipe is displaced, has holes, is clogged 

or is corroded.
This will cause carbon monoxide poisoning 

and a potential fire hazard.
Do not allow anyone to change the water 

temperature while hot water is being used.

To prevent scalding, do not change the water 

temperature to a higher setting.

[When supplying combustion air from the 

indoors]

Check whether or not the air supply vent is 

blocked with dust, trash, a towel, or the like.

Blocking the opening may result in incomplete 

combustion.

Summary of Contents for GQ-C2660WXQ-FF US

Page 1: ...he Canadian Standard CAN CSA Z240 MH Mobile Homes Series M86 Noritz America reserves the right to discontinue or change at any time the designs and or specifications of its products without notice NOR...

Page 2: ...dhesives in the same room or area near the Water Heater Keep flammable products 1 Far away from the Water Heater 2 In approved containers 3 Tightly closed 4 Out of children s reach Vapors 1 Cannot be...

Page 3: ...ualified service technician replace it Do not plug or remove the valve Failure to follow these instructions can result in fire or explosion and personal injury or death Check the temperature of the ru...

Page 4: ...y form inside the unit and or cause incomplete combustion damage to the electrical components or electric leakage Do not turn off the Water Heater while someone is bathing Do not cover the Water Heate...

Page 5: ...internal electrical components For single handle fixtures you d turn the handle to the left This appliance is configured for installations up to 2 000 ft above sea level without changes For installati...

Page 6: ...ial Operation 9 Using the Water Heater 10 Setting Hot Water Temperature 10 Customizable Settings 11 Limiting the Maximum Output Temperature 11 Muting the Remote Controller 12 Flow Meter Alarm 12 Stopp...

Page 7: ...er is discharged from the condensate drain pipe approximately 2 gallons h 7 5 L h maximum It is not a water leak Do not plug or block the drain line as it must always be allowed to freely flow Note Th...

Page 8: ...to the Installation Manual 1 POWER Button Indicator For turning the Water Heater ON OFF 2 SETTINGS Button For setting the flow meter alarm and other settings 3 Buttons For setting the hot water tempe...

Page 9: ...you leave the button on and hot water is not used for more than 3 days the stored recirculation operation will be reset To avoid this turn the button off the Remote Controller when hot water will not...

Page 10: ...g 105 F 2 Set the temperature using the buttons 1 The button is ON Operation The POWER indicator is displayed The previously set hot water supply temperature is shown Setting Hot Water Temperature NOT...

Page 11: ...maximum output temperature can be set using the Remote Controller See Customizable Settings 60 C 140 F Display when high temperature is set e g 125 F NOTE Consult local codes for minimum operating te...

Page 12: ...cannot be muted The high temperature warning tone when setting the unit to 125 F 55 C 131 F or higher will not emit a sound when muted 4 Turn on hot water 5 Turn off the hot water when the alarm sound...

Page 13: ...ixtures to their original levels before using the Water Heater again to prevent scalding If there is still a risk that the Water Heater will freeze drain the Water Heater as shown on the next page 1 T...

Page 14: ...D E F and wait until finish draining water b a Freeze damage due to not draining properly will not be covered under warranty Drain water into a bucket to prevent water damage 9 When the water is compl...

Page 15: ...s been out of use for a long time make sure that you fill the condensate trap with water This is to prevent dangerous exhaust gases from entering the building Failure to fill the condensate trap could...

Page 16: ...to clean the Remote Controller discoloration deformation scratches or cracks may occur The Remote Controller is water resistant but not water proof Keep it as dry as possible Water Drain Valve with W...

Page 17: ...s 500 mg L or less Zinc 5 mg L or less Sulfate 250 mg L or less Residual chlorine 4 mg L or less Source EPA National Secondary Drinking Water Regulations 40 CFR Part 143 3 Maximum limit suggested by N...

Page 18: ...ilable from NRCR111DV GQ C3260WXQ FF US is 8 7 GPM 33 L min at a 45 F 25 C temperature rise The maximum flow available from NRCR92DV GQ C2660WXQ FF US is 7 1 GPM 27 L min at a 45 F 25 C temperature ri...

Page 19: ...ilure occurs information relating to the error blinks on the display If this occurs take appropriate measures as the following list The fan can be heard after operation is stopped A motor can be heard...

Page 20: ...rranty period there will be a charge on any service and service will only be performed if the unit is deemed repairable Noritz will stock repair and maintenance parts for this unit for the time period...

Page 21: ...mplete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit WARNING 1 Before the gas conversion is performed verify the prope...

Page 22: ...on NG 218 W LP 202 W Freeze Prevention 114 W NG 185 W LP 175 W Freeze Prevention 114 W Maximum Current 4 Amps Materials Casing Front Cover Hot dipped zinc aluminum magnesium alloy coated steel w Polye...

Page 23: ...y Period is the one used for a commercial capacity Condition C above 8 10 years or 12 500 operational burn hours whichever occurs first 9 5 years or 6 500 operational burn hours whichever occurs first...

Page 24: ...RITZ AMERICA CORP 11160 Grace Avenue Fountain Valley CA 92708 Phone 714 433 2905 Fax 714 241 1514 4 What is Not Covered by this Warranty Please refer to the Installation Manual and Owner s Guide suppl...