26
Changing Other Features
Adjusting the Temperature Display
Note: The setting must be done within the first 10 minutes of connecting electrical power to the water heater.
Table of Setting Items
Display
Power On/Off Button
Flow Meter Alarm Set buttton
Setting Button
Setting Procedure
1. Turn the water heater off by pressing the Power On/Off Button on the remote controller.
2. Disconnect, then reconnect electrical power to the water heater.
3. Press the Flow Meter Alarm Set Button and hold it in for 2 seconds or more.
4. Press the Flow Meter Alarm Set Button until the remote controller displays item number "12".
5. Press Setting Button " " for 5 seconds or more to change the display units to " [°F / gal] ".
6. Press Setting Button " " for 5 seconds or more to change the display units to " [°C / L] ".
7. To confirm the setting, turn the water heater on by pressing the Power On/Off Button on the
remote controller.
Remote Controller
Item No.
Item
Choices (factory defaults shaded)
12
Celsius / Liter
or
Fahrenheit / Gallon
display mode.
°F / gal
(Fahrenheit / Gallon)
°C / L
(Celsius / Liter)