62
[I:10_rFt (Re Fire Time)]
1 sec.
This function is to set up the interval time in
Heating Mode to prevent inconsistent heating.
If the selected time passes and the Combi Boiler’s
inside temperature drops, this function will
automatically reignite the burner in the Combi
Boiler.
settings: 0 - 20 min
(Default setting =
0 min
)
[I:11_Pot (Pump Overrun Time)]
1 sec.
This mode is to control how long the pump will run
after the heating demand is satisfied.
This setting is to prevent unnecessary running of
the pump and extend the life of the pump.
settings: OFF, 1 - 40 min
(Default setting =
OFF
)
[I:12_bFt (Differential Burner OFF Temperature)]
1 sec.
settings: 0 - 27°F (0 - 15°C)
(Default setting =
13°F (7°C)
)
[I:13_bot (Differential Burner ON Temperature)]
1 sec.
settings: 5 - 27°F (3 - 15°C)
(Default setting =
18°F (10°C)
)
When the internal temperature of the Combi Boiler
is too high or low the unit will stop burning or start
burning.
Burner OFF Temperature
= Heating Set Tempe [I:12_bFt]
Burner ON Temperature
= Heating Set Temperature - [I:13_bot]
[I:14_HPS (Heating Water Pressure Setting)]
1 sec.
This function is to control the water pressure on
the heating side of the Combi Boiler.
This will insure there is enough water inside the
Combi Boiler to operate correctly.
When using the external water feeder, set to the
proper pressure for the external waterfeeder. If
not, the Combi Boiler may shut down frequently.
Water Refilling Pressure
= Setting Pressure - 4 PSI
Water Refilling Stop Pressure
= Setting Pr 2 PSI
settings: 12 - 26 PSI
(Default setting =
12 PSI
)
[I:15_AFA (Auto Feeder Activation)]
1 sec.
This setting can activate or deactivate the Auto
Feeder.
If the heating system does not require the Auto
Feeder operation, set [I:15_AFA] OFF and plug the
Auto Feeder Water Inlet Connection.
To change the setting: Press and hold the or
button
for approximately 2 seconds. (ON→OFF:
button
, OFF→ON:
button
)
settings:
ON (The Auto Feeder is activated.),
OFF (The Auto Feeder is deactivated.)
(Default setting =
ON
)
Installer Mode (Parameter Settings)