Connecting the pump control wire

1. Leave enough slack so that the pump control wires 

will stay connected if the unit is removed from the 

wall.

2. Remove the front cover of the heater (4 screws).

3. Cut off the connector at the end of the pump 

control wires.

4. Wire the pump control wires through the wiring 

throughway and connect them to the wiring inside 

the pump (this will be the power supply for the pump, 

do not also connect 120VAC to the pump).

  If a large pump is being used (greater than 85W) use 

the voltage from these wires as the signal to close a 

normally open relay through which 120VAC will be 

supplied directly from a wall circuit to the pump. 

5. Replace the front cover.

Pump Wiring

* This  feature  is  not  available  when  using  the  Quick 

Connect Multi System feature.

Relay connection with larger pumps (>85 W)

1. Locate and prepare the pump control wires as described above.

2. Choose a suitable installation location for the relay where it will be protected from moisture.

3. Connect the pump control wires from the heater to the signal input on the relay.

4. Cut one of the electrical supply leads and wire it across the open terminals of the relay.

5. Secure all connections and replace the front cover of the heater.

Circulation Pump

120VAC

Relay (ex. Omron G7L2ABUBJCBAC120)

Connect to Pump Control

Wires in Unit

0

1

2

4

PUMP

Crimping Terminal

Wiring

Throughway

Supplies Power for 

Circulating Pump 

(Use a Relay for 

Larger Pumps)

Pump Control  

Wire Tag

Summary of Contents for ecoTOUGH NRC111-OD-NG

Page 1: ...ructed in this manual are not covered by the warranty Check that the installation was done properly in accordance with this Installation Manual upon completion After completing installation please eit...

Page 2: ...ts but may be necessary for installation Cross Recessed Head Screw Quick Connect Cord QC 2 Q ty Shape Part Part Shape Q ty 1 1 Remote Controller Cord 26ft 8m 1 each Isolation Valves includes pressure...

Page 3: ...Block Cord Connector Cord Connector 3 Quick Connect Multi System Installation The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord Typica...

Page 4: ...Other Than Those Specified Do not use for other than increasing the temperature of the water supply as unexpected accidents may occur as a result Check Water Supply Quality If the water supply is in e...

Page 5: ...eat and moisture from the water heater may cause discoloration of walls and resinous materials or corrosion of aluminum materials Do not locate the vent termination directed towards a window or any ot...

Page 6: ...re in width Provide clearance of 24 600mm or more in front of the unit to facilitate inspection and repair Do install the unit such as the wall of the second floor where the unit is out of reach When...

Page 7: ...rdance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sid...

Page 8: ...arts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locating Screw Holes Mounting Structure When installing with bare hands take caution...

Page 9: ...e installer The installer must be professionally trained to do such work and must always follow all local and national codes and regulations Gas line sizing calculations must be performed for every in...

Page 10: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Page 11: ...se 50 15m 175 000 Btuh requires 1 Outlet E 25 7 5m Use 30 9m 199 900 Btuh requires 3 4 Section 4 45 13 5m Use 50 15m 355 000 Btuh requires 1 1 4 Natural Gas Meter Noritz Condensing Tankless Gas Water...

Page 12: ...ce to verify all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION Pi...

Page 13: ...nected to any heating system or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest of the sy...

Page 14: ...r on the inlet If this is not done local boiling will occur inside the water heater causing abnormal sounds and decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented...

Page 15: ...If this water heater will be installed in an application where the supply water is hard the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener Refer to the below t...

Page 16: ...n the other to the circulating pump 4 Connect the drain hose H2 to the circulating pump 5 Connect the drain hose H3 to the drain valve V4 6 Pour 1 gallon of and gallon water into the bucket Noritz rec...

Page 17: ...the flushing solution through the water heater for 1 hour at a rate of 1 5 gallons per minute or more 5 The code C60 is displayed on the Remote Controller when the water heater detects the flow of th...

Page 18: ...pply valves and water out let valves 9 Check for correct operation of the water heaters is displayed when the Main Water Heater s bule connector is connected is displayed when the Sub Water Heater s b...

Page 19: ...as short as possible Long runs or applications where the nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of...

Page 20: ...CE 1 2 PVC pipe DO NOT ADD ANY VALVES DO NOT ADD ANY VALVES Condensing Tankless Gas Water Heater Condensing Tankless Gas Water Heater Note If the drain line becomes clogged or frozen condensate will b...

Page 21: ...ull recirculation waranty If it is not installed the water heater can not detect the Scale Build up in the Heat Exchanger 4 Noritz recommends the use of an Isolation Kit with the installation These ki...

Page 22: ...ly required by the water heater is 120VAC at 60 Hz The power consumption may be up to 303W or higher if using optional accessories Use an appropriate circuit Do not disconnect the power supply when no...

Page 23: ...On Off Button on the remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display This unit can be programmed so that it will default to one of three te...

Page 24: ...the end of the remote controller cord to the terminal block 5 Replace the terminal block cover and install the screw previously removed in step 3 6 Reconnect electrical power to the water heater Exter...

Page 25: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Connect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Page 26: ...mp Ground wire Connector Use one of the vacant holes Connector Connecting Quick Connect Cord 2 Caution For Quick Connect Multi System Installation use part QC 2 only sold separately Quick Connect Cord...

Page 27: ...a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do no...

Page 28: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Page 29: ...0mm 1 4 36mm 0 4 10mm 1 7 44mm 26 2 665mm 23 1 586mm 24 2 615mm 24 0 611mm 2 4 61mm 2 1 53mm 1 6 40mm 0 4 10mm 9 4 240mm 0 5 13mm 1 1 28mm 1 6 42mm 17 7 450mm 18 3 464mm 10 5 267mm 16 9 428mm 3 9 99mm...

Page 30: ...s on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid location...

Page 31: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Page 32: ...he wall pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wa...

Page 33: ...r In order to use this product safely read this installation manual carefully and follow the installation instructions Potential dangers from accidents during installation and use are described below...

Page 34: ...t The value in indicates the quantity Remote Controller Mounting bracket Raised countersunk head wood screw Wall anchor Raised countersunk head screw For junction box installation Machine screw When a...

Page 35: ...f the remote controller and the frame pull the entire decorative frame forward while pressing the sections indicated where the fingers are in the figure below If it does not come off insert a flat hea...

Page 36: ...Button the Misc settings screen appears on the display 4 Select Max set Temp using the Buttons 5 Press the ENTER Button 120 F 50 C appears on the display 6 Set the upper limit of the hot water supply...

Page 37: ...e controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the MENU Button inside the cover select Initial settings using the Buttons 4 Press the ENTER button the Initial se...

Reviews: