Noria ECO:100 Installation & Operation Manual Download Page 5

SETTING THE SPEED

Normal Operation Mode at startup

Press Button:

For ECO Mode (LED will flash when selected)

For MEDIUM Mode (LED will flash when selected)

For HIGH Mode (LED will flash when selected)

Off Button (LED will flash when selected)

NOTE

If power is removed the
motor will return to the last
speed selected when power
is restored

Motor will remember the
ON/OFF state

If there is a fault, the LED
screen will display an error
code - note the error code
and consult your local agent

Adjustable Speed Mode:

(this feature is available following the 5 minute priming period)

Press Button:
Press and Hold:

,

or

for approximately 3 seconds (until the LED begins to flash) to
switch to ‘Adjustable Speed Mode’.

Holding all 3 buttons for 3 seconds will reset the speeds to default.

To decrease selected mode by 25 RPM increments

To save the current speed setting and return to normal operation mode

To increase selected mode by 25 RPM increments

Will cancel the change and revert back to the original speed and return to
normal operation mode

Summary of Contents for ECO:100

Page 1: ...INSTALLATION OPERATION ECO 100 ECO 150...

Page 2: ...The Noria ECO difference continues with the use of stainless steel shafts for strength larger hair and lint pots reduce the need for frequent cleaning The research invested in Noria ECO pumps is refle...

Page 3: ...suring the O rings are attached 40mm and 50mm are supplied depending on the size of pipe 4 Plumb the suction side of the pump to the skimmer suction pipe including any valves required 5 Plumb the disc...

Page 4: ...1 Check all the connections are hand tight 2 Remove the lid from the pump by turning the lock ring anti clockwise put these aside for later use 3 Fill the hair and lint pot with water to the bottom o...

Page 5: ...isplay an error code note the error code and consult your local agent Adjustable Speed Mode this feature is available following the 5 minute priming period Press Button Press and Hold or for approxima...

Page 6: ...around the pump is wet or damp it indicates there is a leak Trace the leak to the source and repair the problem 1 Check to make sure all the barrel unions are tight and O rings are fitted 2 If the pum...

Page 7: ...is used DO NOT use petroleum based products as these result in damage to the O rings The mechanical seal consists of two parts A spring loaded rotating seal with a polished carbon face and a stationar...

Page 8: ...inimum operating head in metres for this appliance is 2m The maximum total head in metres for this appliance is between 2 12m The pump is to be either supplied by an isolating transformer or supplied...